摘要 肺部的呼吸运动会在图像导航穿刺手术中引入误差,并且该误差是穿刺导航手术的主要误差.为解决该问题,提出了一个接近亚体素级精度、方便易用、运算简便的呼吸模型.首先根据肺内部各标记点的真实运动信息推算运动状态参数;然后根据运动状态参数的运动趋势,提取各点运动的总体规律;最后结合已获得的样本数据,得到一个一般化的呼吸模型.交叉实验结果表明,运用该模型可以将由呼吸引起的原始误差降低75%左右,在呼吸幅度较小的情况下,模型可以达到亚体素级的精度,并且具有运算简便、运用简单的特点. Lung respiratory movement can cause errors in the operation of image navigation surgery and they are the main errors in the navigation system. To solve this problem,a convenient,simple and easy-to-use breathing model whose precision was close to the sub-voxel was proposed. Motion parameters were first calculated according to the actual lung movement information of each point. The general movement law of each point was then obtained from the movement trend of the motion parameters. Finally a generic lung breathing modelwas constructed based on all the sample data. Results of cross experiments show that the proposed model can reduce the original errors caused by lung breath by about 75%. Besides,in circumstances of lung breath with small amplitude,the proposed model is simple and easy-to-use and can reach the sub-voxel precision.
出处 《天津大学学报(自然科学与工程技术版)》 EI CAS CSCD 北大核心 2015年第4期298-304,共7页 Journal of Tianjin University:Science and Technology
基金 国家科技支撑计划资助项目(2012BAI14B00)
关键词 呼吸模型 曲线拟合 运动状态参数 误差 breathing model curve fitting motion parameter error
  • 相关文献

参考文献11

  • 1Bal M, Spies L. Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering [J]. Medi- calPhysics, 2006, 33(8): 2852-2859.
  • 2Yu Hengyong, Zeng Kai, Bharkhada D K, et al. A segmentation-based method for metal artifact reduc- tionEJ].AcademicRadiology, 2007, 14(4): 495-504.
  • 3Li Xing, Thomdyke B, Schreibmann E, et al. Over- view of image-guided radiation therapy [J]. Medical Do- simetry, 2006, 31(2): 91-112.
  • 4Keall P, Yamamoto T, Suh Y. Introduction to 4D Mo-tion Modeling and 4D Radiotherapy[M]. Berlin Heidel- berz: SDriner Berlin Heidelberz, 2013.
  • 5McClelland J R, Blackall J M, Tarte S, et al. A con- tinuous 4D motion model from multiple respiratory cy- cles for use in lung radiotherapy [J]. Medical Physics, 2006, 33(9): 3348-3358.
  • 6George R, Vedam S S, Chung T D, et al. The applica- tion of the sinusoidal model to lung cancer patient respi- ratory motion [J]. Medical Physics, 2005, 32 (9) : 2850-2861.
  • 7Vandemeulebroucke J. Lung motion modelling and esti- mation for image guided radiation therapy[EB/OL]. http: //www. creatis, insa-lyon, fr/rio/popi-model, 2012-12-20.
  • 8Murphy K, van Ginneken B, Klein S, et al. Semi- automatic construction of reference standards for evalua- tion of image registration [J]. Medical linage Analysis, 2011, 15(1): 71-84.
  • 9Yamamoto T, Kabus S, Lorenz C, et al. 4D CT lung ventilation images are affected by the 4D CT sorting method[J]. MedicalPhysics, 2013, 40(10) : 101907.
  • 10Heinrich H P, Jenkinson M, Brady S, et al. MRF- based deformable registration and ventilation estimation of lung CT [J]. 1EEE Transactions on Medical Imaging, 2013, 32(7) : 1239-1248.