摘要 目的:探讨输血过程中出现抽取血型标本与患者血型不符的原因以及防范措施。方法回顾性分析与研究郑州市20所医院输血科2008-2012年间发生的抽取血型与患者所需血型不相符的事例,分析输血错误的原因。结果血液标本不符49.6%,取血和输注错误31.2%,仅输注错误15.2%,干细胞移植后血型改变4.0%,导致血液标本错误的原因主要有血液中心或者血站提供的血液与标识血型不符16.13%、用血申请单填写错误20.97%、检验血型错6.45%、血液标本取错29.03%、血液标本标签贴错27.42%。结论为确保临床用血安全,必须采取防范措施坚决杜绝血液标本错误的发生。 Objective To study the reason and preventive measures of inconformity of the extraction appeared in the process of transfusion blood specimens with the patient's blood type.Methods The reasons of transfusion errors why extracting required blood type was not consistent with the patient's blood type examplesa in Zhengzhou transfusion of hospital from 2008 to 2012 were retrospectively analyzed.Results The experimental results showed that blood specimen inconformity was 49.60%,the error rate of blood extraction and blood infusion was 31.20%,infusion error only was 15.20%,blood type change after stem cell transfusion was 4.00%.Reasons of blood type change after stem cell transplantation to extract blood samples mainly included the blood center or blood did not accord with logo type blood stations provided (16.13%),blood use application form to fill in error(20.97%),check the wrong blood type (6.45%),blood samples taken(29.03%),the blood sample tag(27.42%).Conclusion In order to ensure the safety for clinical use must adopt measures to prevent resolutely put an end to a blood transfusion errors.
出处 《中国基层医药》 CAS 2015年第7期1011-1014,共4页 Chinese Journal of Primary Medicine and Pharmacy
关键词 血液标本错误 输血 血型 Blood sample errors Blood transfusions Bloodtype
  • 相关文献

参考文献12

  • 1Klein HG, Anstee DJ. Mollison blood transfusion in clinical med- icine[ M]. John Wiley & Sons,2013,23 (21) :45-47.
  • 2Glance LG, Dick AW, Mukamel DB, et al. Association between intraoperative blood transfusion and mortality and morbidity in pa- tients undergoing noncardiac surgery [ J ]. Anesthesiology, 2011, 114(2) :283-292.
  • 3Cho MS,Song MR,3ang MR. Evaluation of the bar code medica- tion administration and blood transfusion system in a tertiary Hos- pital[ J]. J Korean Acad Nurs Administrat,2012,18 (1) :23-32.
  • 4Grimm E, Friedberg RC, Wilkinson DS, et al. Blood bank safety practices: mislabeled samples and wrong blood in tube-A Q- Probes analysis of 122 clinical laboratories[ J]. Arch Pathol Labo- rat Med,2010,134(8) :1108-1115.
  • 5Doctor J N, Strylewicz G. Detecting ' wrong blood in tube'errors : Evaluation of a Bayesian network approach [ J ]. Art Int Med, 2010,50(2) :75-82.
  • 6徐艳,文永.血型鉴定错误原因分析[J].检验医学与临床,2011,8(11):1356-1357. 被引量:9
  • 7郭永建.筑牢血液标本采集错误的防控机制——血型2次检测结果比对要求之习得与实施策略[J].中国输血杂志,2013,26(6):595-600. 被引量:12
  • 8卫生部.关于印发《血站技术操作规程(2012版)》的通知(卫医政发[2012]1号),2011,12-31.
  • 9卫生部.关于印发《临床输血技术规范》的通知(卫医发[2000]184号),2000-06-02.
  • 10杨育红,陈进凡,董晓梅.对血型鉴定及交互配血差错标本的分析及对策[J].甘肃科技,2013,29(6):123-123. 被引量:2

二级参考文献37

  • 1胡继征,陆典瑞,李启辉.全自动微板法检测28379例献血者ABO血型的统计分析[J].国际医药卫生导报,2003,9(18):75-76. 被引量:10
  • 2邢文革,马嵘,郑怀竞.国内血站血型血清学检验的状况调查[J].中国输血杂志,2004,17(3):188-190. 被引量:9
  • 3孙家志.采血车血型错误原因分析.医学检验与临床,2009,20(2):113-114.
  • 4杰夫·丹尼尔著,朱自严主译.人类血型.北京:科学出版社,2007:331-332.
  • 5GB18467-2011.献血者健康检查要求.
  • 6卫生部.关于印发《血站技术操作规程(2012版)》的通知(卫医政发[2012]1号).2011-12-31.
  • 7卫生部.关于印发《血站质量管理规范》的通知(卫医发[2006]167号.2006-04-25.
  • 8全血及成分血质量要求.GB18469-2012.
  • 9卫生部.血站管理办法(卫生部令第44号).2005-1147.
  • 10Dzik WS, Beckman N, Selleng K, et al. Errors in patient specimen collection:applicaton of statistical process con- troL Transfusion,2008,48(10) :2143-2151.