摘要
通过搭建串联电弧检测试验平台,在不同功率的阻性负载下,采集正常和发生串联故障电弧状态下的线路电流,并分析了电流的时域特征和频域特征,包括零休时间、电流上升率、平均值、有效值以及各奇次、偶次谐波因数等。 分析结果表明,选择 2~6 次谐波因数及其变化率作为串联故障电弧的判据较为合理。
A test platform of series arc faults is constructed and the line current is acquired in normal and series arc fault conditions for different resistive load powers. The time- and frequency-domain characteristics of the line currents acquired are analyzed,including rising rate, average,RMS,arc interval,odd/even harmonic factors and so on. The analytical results show that,the 2 to 6-order harmonic factors and their variation rates should be selected as the criteria of series arc fault detection.
出处
《电力自动化设备》
EI
CSCD
北大核心
2015年第5期106-110,118,共6页
Electric Power Automation Equipment
关键词
电弧
断路器
阻性负载
时域分析
频域分析
傅里叶变换
谐波因数
谐波分析
electric arcs
electric breakers
resistive load
time domain analysis
frequency domain analysis
Fourier transforms
harmonic factor
harmonic analysis