摘要 目的通过口腔专用锥形束CT技术探究下颌神经管磨牙后区分支的相关数据以及其与该区位置的关系,为临床外科手术提供理论依据。方法收集和分析316例中国人锥形束CT扫描数据,筛选有下颌管磨牙后区神经分支的病例,并对其进行长度、第二磨牙远中根的距离、颊侧骨板和舌侧的距离测量分析。结果下颌神经管磨牙后区分支的平均长度为(3.41±1.44)mm;下颌神经管磨牙后区分支的末端与下颌第二磨牙远中根的距离的平均值为(12.83±5.43)mm,其末端距离唇颊侧骨板的平均值为(6.18±1.73)mm;距离牙槽嵴顶的平均值为(18.47±6.34)mm;距离舌侧骨板的平均值为(5.79±1.67)mm。结论在种植手术和拔除阻生牙等外科手术之前,使用锥形束CT对其具体位置进行多平面重建并进行分析,能够减少术后并发症的发生。 Objective To analyse the length of mandibular canal branch in retromolar region and its relation to the operation using CBCT,providing theoretical basis for the clinical surgery. Method CBCT data of 316 Chinese people were collected,and screening with cases of mandibular canal branch in retromolar region. Result The length of man-dibular canal branch in retromolar region was (3. 41±1. 44) mm,to the distal root of the mandibular second molar was (12.83±5.43)mm,to buccal bone plate was (6.18±1.73)mm,to alveolar crest was (18.47±6.34)mm,to Lingual bone plate was (5. 79±1. 67)mm. Conclusion There is a probability of the existence of the branch in retro-molar region in the people,clinicians should use CBCT before implant or maxillofacial surgery procedures to mini-mize the risk of inferior alveolar nerve injury.
出处 《中国医刊》 CAS 2015年第3期71-74,共4页 Chinese Journal of Medicine
基金 浙江省自然科学基金项目(Y2101392)
关键词 下颌神经管 磨牙后区分支 锥形束CT 锥形束CT Mandibular canal Retromolar region branch CBCT
  • 相关文献

参考文献19

二级参考文献60

  • 1李任,仇丽鸿.牙髓卟啉单胞菌内毒素致病性研究进展[J].中国实用口腔科杂志,2009,2(12):756-758. 被引量:22
  • 2涂滔,张强.纵向折裂牙治疗的探讨[J].江两医药,2008,43(12):1394-1395.
  • 3Chai X, van Herk M, Bergen A,et al. Automatic bladder segmenta- tion on CBCT for muhiple plan ART of bladder cancer using apa- tient-specific bladder model [ J ]. Phys Med Biol, 2012, 57 (12) :3945.
  • 4Mozzo P, Procacci C, TacconiA, et al. A new volumetric CT ma- chine fordental imaging based on the cone-beam technique:prelim- inary results [ J]. Eur Radiol, 1998,8 (9) : 1558 - 1564.
  • 5Arai Y,Tammisalo E, Iwai K,et al. Development of a compact com- puted tomographic apparatus for dental use [ J ]. Dentomaxillofac Radiol, 1999,28 ( 4 ) :245 - 248.
  • 6Hashimoto K, Kawashima S, Kameoka S,et al. Comparison of image validity between cone beam computed tomography for dental use and muhidetector row helical computed tomography[ J ]. Dentomax- illofac Radio1,2007,36 ( 8 ) :465 - 471.
  • 7Lindh C, Petersson A. Radiologic examination for location of the mandibular canal: a comparison and conventional tomography [ J ] 1989,4 (3) :249 - 253.
  • 8Wadu SG, Penhall B, Townsend GC. Morphological variability of the human inferior alveolar nerve [ J ]. Clin Anat, 1997,10 (2) :82 -87.
  • 9Yamada T, Ishihama K, Yasuda K. Inferior alveolar nerve canal and branches deteeted with dental cone beam computed tomography in lower third molar region [ J]. Oral Maxillofae Surg, 2011,69 ( 5 ) : 1278 - 1282.
  • 10Carter RB. The intra mandibular canal:report of the inferior alveo- lar nerve[J]. Anat,1971,108:433.

共引文献17

同被引文献13

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部