摘要
目前阀控密封铅蓄电池作为通信用备用电源,备用状态下均采用浮充电方式进行充电管理。由于铅蓄电池对温度非常敏感,要求工作温度在20~30℃,冬天和夏天分别利用空调进行温度调节。文章介绍了阀控铅蓄电池的温度特性,分析目前蓄电池浮充管理中存在的问题,提出了一种蓄电池浮充节能技术。
Currently, as a power supply for communication, valve-regulated lead-acid (VRLA) battery is managed by float charging. The lead-acid battery is very sensitive to the temperature, so the ambient temperature is required between 20℃ and 30℃, and air-condition is used to regulate temperature in winter and summer. The temperature propety of valve-regulated lead-acid batteries is introduced in this paper, and the existing problems in the management of float charging for lead-acid batteries is analyzed. And an energy-saving technology for VRLA battery's free float charging is pointed put.
出处
《电池工业》
CAS
2014年第5期318-319,323,共3页
Chinese Battery Industry
关键词
阀控密封铅蓄电池(VRLA)
温度
浮充电
节能
valve regulated lead-acid battery(VRLA)
temperature
float charging
energy saving