期刊文献+

某钢筋混凝土框架-核心筒结构的动力特性试验

A Reinforced Concrete Frame- Core Tube Structure Dynamic Characteristics Test
下载PDF
导出
摘要 建筑装潢会导致结构主体隐蔽,同时也使得结构缺陷以及损伤处于隐蔽、不可见状态。为判定结构的工作状况,可采用动力特性试验的方法对结构的整体工作性能进行研究。以某钢筋混凝土框架-核心筒结构为研究对象,采用脉动法对结构进行了动力特性试验,并建立有限元模型进行计算和比较分析,对结构的工作状况作出了评价。 Building decoration can cause structure body hidden,at the same time also makes the structure defects and damage hidden and invisible. To determine the working condition of structure,the dynamic characteristics test method can be used to study the overall work performance of the structure. With a reinforced concrete frame - core tube structure as the research object,the pulsating method is adopted for structure dynamic characteristic test,and to establish the finite element model to calculate and make a comparative analysis,and the working condition of the structure is evaluated.
作者 高艳斌
出处 《建材技术与应用》 2015年第2期4-8,共5页 Research and Application of Building Materials
关键词 钢筋混凝土结构 框架-核心筒结构 脉动法 有限元 频率 振型 reinforced concrete structure frame-core tube structure pulsating method finite element method frequency vibration mode
  • 相关文献

参考文献5

  • 1JGJ3-2002高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2002.
  • 2姚起杭.振动环境试验方法和力限试验技术简介[R].西安:西北工业大学振动冲击噪声工程技术中心,2014.
  • 3沈松,应怀樵,葛宝珊,等.云智慧测试技术的实现构架研究[A].应怀樵.现代振动与噪声技术(第10卷)[C].北京:航空工业出版社,2012.
  • 4GB50010--2011,混凝土结构设计规范[S].北京:中国建筑工业出版社,2010.
  • 5GB50011-2010,建筑抗震设计规范[s].北京:中国建筑工业出版社,2009.