轨道检查仪检定台实际超高的测量不确定度分析 被引量:1

Measurement Uncertainty Degree Analysis for the Actual Super Elevation of Calibrater for Track Inspection Instrument
下载PDF
导出
摘要 铁路轨道检查仪检定台采用直接测量法的测量结果作为检定台的实际超高,由此简单地把直接测量法的测量不确定度作为检定台实际超高的测量不确定度是不准确的。首次将检定台的机械装配误差作为不确定度分量引入实际超高的测量不确定度的评定中,计算结果表明:综合考虑机械装配误差后,实际超高的扩展不确定度为0.073 mm,而考虑前仅为0.007mm。指出机械误差的重要影响,对检定台其他方面的测量不确定度评定具有一定的借鉴意义。 The calibrater for track inspection instrument adopts the measurement result by direct measurement method as actual super elevation of calibrater for track inspection instrument. It is inaccurate to take the measurement uncertainty of direct measurement method as the uncertainty of actual super elevation. It is the first to take assembly error of the calibrater into consideration for the uncertainty evaluation of the actual super elevation. Calculation shows that the uncertainty of actual super elevation by traditional is only 0. 007 ram, but after taking the mechanical error into consideration, it can reach 0. 073 mm. The result indicates that the mechanical error take great influence and this provide reference for the uncertainty evaluation of the calibrater in other aspects.
出处 《科学技术与工程》 北大核心 2015年第11期226-228,238,共4页 Science Technology and Engineering
基金 铁道部科技开发重点项目(2012G003-B)资助
关键词 铁路轨道检查仪 检定台 测量不确定度 机械误差 实际超高 track inspection instrument calibrater measurement uncertainty mechanical error actual super elevation