期刊文献+

机用Pathfile^(TM)联合手用ProTaper镍钛器械预备磨牙狭窄根管125例效果评价 被引量:2

Evaluation of the effect of Pathfile^(TM) for machine combined with Pro Taper for hand nickel-titanium instrument in preparing molar narrow root canal in 125 cases
原文传递
导出
摘要 目的探讨机用PathfileTM镍钛锉联合手用ProTaper镍钛器械在磨牙狭窄根管的预备效果。方法选择2011年8月至2012年2月广州市天河区人民医院口腔科门诊需行根管治疗的磨牙根管狭窄患者125例(患牙125颗),采用PathfileTM镍钛锉进行根管预处理,以手用Pro Taper镍钛器械完成根管预备,侧向加压技术充填根管,根据治疗前后的X线片评价根管预备和充填效果。结果 125颗患牙的419个根管中,409个形态好,7个未能完全疏通,无台阶、根尖堵塞、根管偏移及侧壁穿孔等并发症发生,有3根器械折断于根尖段。恰填403个根管,10个根管因未完全疏通、无法到达根尖孔或断针而欠填,6个根管超填。结论采用机用PathfileTM镍钛锉疏通狭窄根管的根尖段后再以手用ProTaper镍钛器械完成根管预备,可获得良好的成形效果且较少出现并发症。
出处 《中国实用口腔科杂志》 CAS 2015年第4期242-243,247,共3页 Chinese Journal of Practical Stomatology
基金 广州市天河区科学技术计划项目(119KW103)
关键词 根管预备 镍钛器械 狭窄根管 root canal preparation nickel-titanium instrument narrow root canal
  • 相关文献

参考文献5

二级参考文献40

  • 1徐琼,樊明文,范兵,凌均棨,陈罕,韦曦.机用镍钛器械预备弯曲根管的临床应用[J].华西口腔医学杂志,2005,23(4):286-288. 被引量:30
  • 2彭彬,沈雅,樊明文.牙体牙髓临床治疗 Ⅳ.镍钛合金根管器械折断的临床特点及防治[J].中华口腔医学杂志,2006,41(5):309-312. 被引量:27
  • 3Schneider SW.A comparison of canal preparation in straight and curved mot canals[J].Oral Surg,1971,32:271-275.
  • 4Pruett JP,Clement DJ,Carries DL.Cyclic fatigue testing of nickel-titanium endodontic instruments[J].J Endod,1997,23:77-85.
  • 5Cunningham CJ,Senia ES_ A three-dimensional study of canal curvatures in the mesial mots of mandibular molars[J].J Endod,1992,18:294-300.
  • 6Dobb NC,Jānos S,J d zsef S.A mathematically based classification of mot canal curvatures on natural human teeth[J].J Endod,1995,21:557-560.
  • 7Schafer E,Dize C,Hoppe W,et al.Roentgenographic investigation of frequency and degree of canal curvatures in human permanent teeth[J].J Endod,2002,28:211-216.
  • 8Roland DD,Andelin WE,Browning DF,et al.The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments[J].J Endod,2002,28:543-545.
  • 9Hata G,Uemura M,Kato AS,et al.A comparison of shaping ability using Profile,GT file,and Flex-R endodontic instruments in simulated canals[J].J Endod,2002,28:316-231.
  • 10Contreras MA,Zinman EH,Kaplan SK.Comparison of the first file that fits at the apex,before and after early flaring[J].J Endod,2001,27:113-116.

共引文献32

同被引文献23

引证文献2

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部