期刊文献+

Risk of connective—tissue disease in men with testicular or penile prostheses:a preliminary study

Risk of connective-tissue disease in men with testicular or penile prostheses: a preliminary study.
下载PDF
导出
摘要 AIM: To help clarifying the possibility of connective-tissue diseases in men with penile or testicular prostheses. METHODS: Eight patients underwent inflatable penile prostheses and 15, testicular prostheses consented to the study. Their medical records were reviewed and a follow-up interview and physical and serological examinations were performed. RESULTS: In patients with penile prostheses, there was no abnormal antinuclear antibody (ANA) or IgM elevation. The serum levels of the rheumatoid factor (RF), C4, IgA and IgG were abnormal in one patient, and the levels of erythrocyte sedimentation rate (ESR) and C3, abnormal in two. Four had elevated IgE. In patients with testicular prostheses, there was no abnormal RF, ANA or IgM. The serum levels of ESR and IgA were abnormal in two, and three had abnormal C4, ten abnormal C3, and eleven decreased IgG. All had increased IgE. Men with penile prostheses had higher serum levels of IgG and IgM than those with testicular prostheses (P=0.001, P=0.016, respectively). The rates of abnormal values of IgE and IgG were higher in men with testicular prostheses than in men with penile prostheses (P=0.008, P=0.009, respectively). Physical examination was normal in all patients and nobody had documented symptoms pertinent to connective-tissue diseases. CONCLUSION: Our findings suggest that the risk of connective-tissue diseases is not higher in patients wearing prostheses as the ANA is negative and there is no apparent manifestation suggestive of connective-tissue diseases. AIM: To help clarifying the possibility of connective-tissue diseases in men with penile or testicular prostheses. METHODS: Eight patients underwent inflatable penile prostheses and 15, testicular prostheses consented to the study. Their medical records were reviewed and a follow-up interview and physical and serological examinations were performed. RESULTS: In patients with penile prostheses, there was no abnormal antinuclear antibody (ANA) or IgM elevation. The serum levels of the rheumatoid factor (RF), C4, IgA and IgG were abnormal in one patient, and the levels of erythrocyte sedimentation rate (ESR) and C3, abnormal in two. Four had elevated IgE. In patients with testicular prostheses, there was no abnormal RF, ANA or IgM. The serum levels of ESR and IgA were abnormal in two, and three had abnormal C4, ten abnormal C3, and eleven decreased IgG. All had increased IgE. Men with penile prostheses had higher serum levels of IgG and IgM than those with testicular prostheses (P=0.001, P=0.016, respectively). The rates of abnormal values of IgE and IgG were higher in men with testicular prostheses than in men with penile prostheses (P=0.008, P=0.009, respectively). Physical examination was normal in all patients and nobody had documented symptoms pertinent to connective-tissue diseases. CONCLUSION: Our findings suggest that the risk of connective-tissue diseases is not higher in patients wearing prostheses as the ANA is negative and there is no apparent manifestation suggestive of connective-tissue diseases.
作者 KuJH SongYS
出处 《Asian Journal of Andrology》 SCIE CAS CSCD 2002年第1期67-72,共6页 亚洲男性学杂志(英文版)
关键词 ADOLESCENT Adult Aged Aged 80 and over Blood Sedimentation Complement C3 Complement C4 Connective Tissue Diseases Humans Immunoglobulin A Immunoglobulin E Immunoglobulin G Immunoglobulin M Male Middle Aged Penile Prosthesis Pilot Projects Risk Factors Silicon Adolescent Adult Aged Aged, 80 and over Blood Sedimentation Complement C3 Complement C4 Connective Tissue Diseases Humans Immunoglobulin A Immunoglobulin E Immunoglobulin G Immunoglobulin M Male Middle Aged Penile Prosthesis Pilot Projects Risk Factors Silicon
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部