摘要 采用EnergyPlus软件研究了非空调条件下电致变色玻璃窗对室内空气平均温度和热舒适的影响。结果表明,与Low-E玻璃窗相比,夏季和秋季电致变色玻璃窗房间室温高于29℃的时间分别减少了217h和13h,春季、夏季和秋季的舒适时间分别增加了19,135,132h。电致变色玻璃窗可以改善室内热环境并提高室内的热舒适。 Based on the use of the EnergyPlus software,analyses the effect of Low-E window and electrochromic window on indoor mean air temperature and thermal comfort in a residential building in Shanghai under non-air-conditioned environment.The results show that compared with the Low-E window, the cumulative time of the room temperature higher than 29 ℃in the room with the electrochromic window decreases 217 hours in summer and 13 hours in autumn respectively.Meanwhile,the thermal comfortable time increases 19 hours in spring,135 hours in summer,132 hours in autumn respectively.Electrochromic window can improve indoor thermal environment and thermal comfort.
机构地区 同济大学
出处 《暖通空调》 北大核心 2015年第5期74-76,70,共4页 Heating Ventilating & Air Conditioning
关键词 电致变色玻璃 居住建筑 室内平均温度 热舒适 热环境 electrochromic window, residential building, indoor mean air temperature, thermal comfort, thermal environment
  • 相关文献

参考文献7

  • 1王立祥,王兆祥.浅析电致变色玻璃中的电致变色材料[J].玻璃,2011,38(4):26-29. 被引量:3
  • 2Hartmut W. Electrochromics for architectural glazing applications [C]// The Glass Processing Days Conference. Finland, 1997.
  • 3Assimakopoulos M N, Tsangrassoulis A, Santamouris M. Comparing the energy performance of an electrochromic window under various control strategies[J]. Building and Environment, 2007, 42 (8) :2829-2834.
  • 4梁庆,徐刚,徐雪青.电致变色玻璃窗节能特性分析[J].材料研究与应用,2008,2(4):470-474. 被引量:9
  • 5Lee E S' Tavil A. Energy and visual comfort performance of eleetrochromic windows withoverhangs[J]. Building and Envirolmaent, 2007, 42 (6) : 2439- 2449.
  • 6Fang Yueping, Hyde T, Hewitt N, et al. Thermal per{ormance analysis of an electrochromic vacuum glazing with low emittance coatings [J]. Solar Energy, 2010,84(4) :516-525.
  • 7Schiavon S, Lee K H. Dynamic predictive clothing insulation models based on outdoor air and indoor operative temperatures [ J]. Building and Environment, 2013, 59 : 250- 260.

二级参考文献20

  • 1朱泉峣,靳艾平,陈文.智能窗中电致变色材料的研究进展[J].国外建材科技,2006,27(1):4-7. 被引量:7
  • 2张建荣.透明导电氧化物材料的应用与开发[J].新材料产业,2006(8):51-54. 被引量:3
  • 3高玲,尚福亮,杨海涛,韩海涛.溶胶-凝胶-热解法制备介孔WO_3薄膜及其电致变色性能研究[J].功能材料,2007,38(1):75-77. 被引量:14
  • 4何延春,邱家稳.直流磁控溅射沉积WO_3薄膜电致变色性能研究[J].真空与低温,2007,13(1):16-20. 被引量:11
  • 5[5]LAMPERT C M.Smart switchable glazing for solar energy and daylight control[J].Solar Energy Materials and Solar Cells,1998,52(3-4):207-221.
  • 6[6]PAPAEFTHIMIOU S,LEFTHERIOTIS G,YIANOULIS P,et al.Development of electrochromic evacuated advanced glazing[J].Energy and Buildings,2006,38(12):1455-1467.
  • 7[7]LEE E S,DIBARTOLOMEO D L.Application issues for large-area electrochromic windows in commercial buildings[J].Solar Energy Materials and Solar Cells,2002,71(4):465-491.
  • 8[8]AZENS A,GRANQVIST C G.Electrochromic smart windows:energy efficiency and device aspects[J].Journal of Solid State Electrochemistry,2003,7(2):64-68.
  • 9[9]GUGLIERMETTI F,BISEGNA F.Visual and energy management of electrochromic windows in Mediterranean climate[J].Building and Environment,2003,38(3):479-492.
  • 10[10]SULLIVAN R,LEE E S,PAPAMICHAEL K,et al.Effect of switching control strategies on the energy performance of electrochromic windows[C]//Optical Materials Technology for Energy Efficiency and Solar Energy Conversion XIII,Freiburg,Germany:SPIE,1994,2255:443-455.