摘要
采用ASTMC1202快速氯离子渗透试验方法研究蒸养矿渣混凝土的抗渗性能,对试验所用材料及试验设计方法作了说明,试验结果表明:采用矿渣等量取代部分水泥,可以有效提高蒸养混凝土抗氯离子渗透性能。
The paper adopts ASTMC1202 rapid chloride permeability test to study the anti-seepage performance of the steamed slag concrete, il-lustrates the materials in the test and its design methods, and proves by the test result that the slag’ s equivalent replacement of partial cement can improve the anti-chloride permeability of the steamed concrete effectively.
出处
《山西建筑》
2015年第15期113-114,共2页