杭州东方君悦综合楼给排水及消防系统设计 被引量:1

Design and Reflection of Water Supply and Drainage Systems and Fire Water System for Dongfangjunyue Building Complex
原文传递
导出
摘要 东方君悦是一座包括酒店、公寓、商业等功能的综合建筑,其中一幢塔楼为超高层建筑,给水系统和消防系统均采用了中间水箱串联供水,并做了合理的竖向分区。详细介绍了各系统的设计参数,并对消防系统阀门设置、装修喷头布置、生活用水点水压以及自喷系统末端试水等问题提出了自己的观点和解决方法。 Dongfangjunyue is a building complex including hotel, apartment and commercial buildings of which one is a super high-rise building. Both water supply system and fire water system adopt water supply systems with intermediate water tanks in series, and there is a rational vertical division of water supply. The design parameters of various systems were introduced. Suggestions on valve setting in fire water system, layout of sprinkler with decoration, water pressure at fixture inlets and the drainage for sprinkler system testing were made.
作者 胡晓琼
出处 《中国给水排水》 CAS CSCD 北大核心 2015年第10期41-44,共4页 China Water & Wastewater
关键词 超高层建筑 给水排水系统 水消防系统 阀门设置 super high-rise building water supply and drainage systems fire water system valve setting
  • 相关文献

参考文献5

  • 1GB50015-2003建筑给水排水设计规范[S].北京:中国计划出版社,2003.
  • 2GB50015-2003,建筑给水排水设计规范(2009年版)[S].北京:中国计划出版社,2010.
  • 3GB50045--95,高层民用建筑设计防火规范(2005年版)[s].北京:中国标准出版社,2005.
  • 4GB50084-2001,自动喷水灭火系统设计规范(2005年版)[S].北京:中国计划出版社,2005.
  • 5GB50555--2010,民用建筑节水设计标准[S].北京:中国建筑工业出版社,2010.