期刊文献+

脊髓病手功能评测系统的开发及软件实现 被引量:2

Development of Myelopathy-Hand Function Evaluation System and Software Implementation
下载PDF
导出
摘要 目的基于数据手套(Date-glove)技术结合计算机编程软件,开发脊髓病手功能评测系统(MFS)。方法分别选取确诊脊髓型颈椎病(CSM)患者及健康成年人各20例作为研究对象,应用Wise Glove数据手套获取10 s手屈伸测试(GRT)掌指关节的活动动态信号,以Visual C++为编程工具编写计算机软件模拟掌指关节的角度变化。结果 CSM组左手10 s GRT平均15.20次/10 s,右手平均15.45次/10 s,健康对照组左手平均23.42次/10 s,右手平均23.63次/10 s,两组同侧10 s GRT测试结果差异有统计学意义(P<0.05),CSM患者存在不同程度的手部功能下降。结论 MFS具有集成度高、无创、定量、可靠、操作简便等特点,并首次采用Date-glove技术对脊髓病手功能进行量化分析。 Objective To develop a MFS (Myelopathy-Hand Function Evaluation System) in combination with computer programming based on the data glove technology. Methods Altogether 20 confirmed CSM (Cervical Spondylotic Myelopathy) patients and 20 healthy volunteers were selected respectively in this study. With deployment of the WiseGlove data glove, motion signals of the metacarpophalangeal joint during 10-s GRT (Grip and Release Test) were acquire dand processed by the computer software based on VC++programming to simulate the angular changes of the metacarpophalangeal joint. Results The average 10-s GRT results of the left and right hands in CSM Group were 15.20 times/10 s and 15.45 times/10 s respectively in contrast with 23.42 times/10 s and 23.63 times/10 s in Control Group. Statistically significant differences existed in the 10-s GRT results of the same-sided hands between two groups (P〈0.05). Hand functions were deteriorated to various degrees in patients with CSM. Conclusion With the ifrst ever adoption of the data glove technology, MFS had demonstrated its high-integration, noninvasive, quantitative, reliable and easy-to-operate features in quantitative analysis of myelopathy-hand functions.
出处 《中国医疗设备》 2015年第5期24-27,共4页 China Medical Devices
基金 长海医院1255计划基金(CH125520900) 上海市新百人计划项目基金资助项目(XBR2013099)
关键词 脊髓型颈椎病 手功能障碍 数据手套 功能评价 量化评估 手指屈伸试验 cervical spondylotic myelopathy hand dysfunction data glove function assessment quantitation evaluation grip and release tests
  • 相关文献

参考文献14

  • 1Ono K,Ebara S,Fuji T,et al.Myelopathy hand.New clinical signs of cervical cord damage[J].J Bone Joint Surg Br,1987,69(2):215-219.
  • 2Prabhu K,Babu KS,Samuel S,et al.Rapid opening and closing of the hand as a measure of early neurologic recovery in the upper extremity after surgery for cervical spondylotic myelopathy[J]. Arch Phys Med Rehabil,2005,86(1):105-108.
  • 3Hosono N,Makino T,Sakaura H,et al.Myelopathy hand:new evidence of the classical sign[J].Spine(Phila Pa 1976),2010,35(8): E273-277.
  • 4Yukawa Y,Nakashima H,Ito K,et al.Quantifiable tests for cervical myelopathy;10-s grip and release test and 10-s step test:standard values and aging variation from 1230 healthy volunteers[J].J Orthop Sci,2013,18(4):509-513.
  • 5Kandori A,Miyashita T,Hosono N,et al.Motion analysis of grip and release with fingers using simple magnetic detection system[J].Rev Sci Instmm,2007,78(3):034302.
  • 6Harrop JS,Naroji S,Maltenfort M,et al.Cervical myelopathy:a clinical and radiographic evaluation and correlation to cervical spondylotic myelopathy[J].Spine(Phila Pa 1976),2010,35(6):620-624.
  • 7姜红,王利,张兆臣.虚拟现实技术在医学中的应用[J].中国医疗设备,2008,23(8):49-52. 被引量:10
  • 8Levoy M.Display of surfaces from vohlme data[J].IEEE Comput Graph AppI,1 988,8(3) :29-37.
  • 9Ip HH,Lam MS,Law KC,et al.Animation of hand motion from target posture images using an anatomy-based hierarchical model[J].Comput Graph,2001,25:121-133.
  • 10Kaneko T,Muraki T.Development and standardization of the hand function test[J].Bull Allied Med Sci,1990,6:49-54.

二级参考文献21

共引文献9

同被引文献36

引证文献2

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部