期刊文献+

APF铁心电抗器的直流偏磁现象及其优化设计

DC Magnetic Bias and Improved Design of Iron-core Reactor in APF
下载PDF
导出
摘要 有源电力滤波器(APF)中耦合铁心电抗器的参数对于整体装置的工作性能有较大影响,在此针对APF装置中的铁心电抗相关问题进行了分析研究,指出装置实际工作过程中的各类因素会使得输出电流中含有直流分量,从而使铁心产生直流偏磁现象,并且以三相四线制APF为例进行了仿真分析,指出直流偏磁所产生的影响。最后从不同方面介绍了几种相应的改善方法,并以三相铁抗为例对改善效果进行了实验验证。 This paper discusses the issues of iron-core parallel reactor in APF, and points out that the phenomenon of DC magnetic bias will occur by dc component in output current.This phenomenon is expressed in detail by theoretical analysis and has been simulated on three-phase four-wire parallel APF under Matlab environment, with or without DC magnetic bias.The results show that DC magnetic bias is the main cause of even harmonic and furthermore affects the APF filtering performance.Some kinds of optimization method are proposed, and experiments with three-phase ironcore reactor prove the effect.
出处 《电力电子技术》 CSCD 北大核心 2015年第5期38-41,共4页 Power Electronics
关键词 有源电力滤波器 铁心电抗 直流偏磁 active power filter iron-core reactor DC magnetic bias
  • 相关文献

参考文献7

二级参考文献60

共引文献177

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部