摘要
应用ANSYS有限元软件和SW6软件对脱硫吸收塔进行结构计算分析,在不同载荷作用下得到结果进行对比分析,发现地震载荷以均匀的水平加速度施加的加载方式的有限元计算结果与常规计算相对误差较大。
The structure of the flue gas desulfuration absorbing tower ment method analysis software ANSYS and compared with results from nite element method calculation results with conventional seismic load is analyzed by means of finite ele- SW6 software. loading applied It is found that fi- in a uniform horizontal acceleration of the relative error is large.
出处
《有色设备》
2015年第2期19-22,共4页
Nonferrous Metallurgical Equipment
关键词
脱硫吸收塔
有限元分析
地震载荷
flue gas desulfuration absorbing tower
finite element analysis
seismic loads