Improved thromboresistance and analytical performance of intravascular amperometric glucose sensors using optimized nitric oxide release coatings

Improved thromboresistance and analytical performance of intravascular amperometric glucose sensors using optimized nitric oxide release coatings
原文传递
导出
摘要 In this work, nitric oxide (NO) release coatings designed for intravenous amperometric glucose sensors are optimized through the use ofa polylactic acid (PLA) layer doped with a lipophilic diazeniumdiolated species that releases NO through a proton-driven mechanism. An Elast-Eon E2As polyurethane coating is used to both moderate NO release from the sensor surface and increase the sensor's linear detection range toward glucose. These sensors were evaluated for thromboresistance and in vivo glucose performance through implantation in rabbit veins. By maintaining NO flux on a similar scale to endogenous endothelial cells, implanted glucose sensors exhibited reduced surface clot formation which enables more accurate quantitative glucose measurements continuously. An in vivo time trace of implanted venous sensors demonstrated glucose values that correlated well with the discrete measurements of blood samples on a benchtop point-of-care sensor-based instrument. The raw measured currents from the implanted glucose sensors over 7 h time periods were converted to glucose concentration through use of both a one-point in vivo calibration and a calibration curve obtained in vitro within a bovine serum solution. Control sensors, assembled without NO release functionality, exhibit distinctive surface clotting over the 7 h in vivo implantation period. In this work, nitric oxide (NO) release coatings designed for intravenous amperometric glucose sensors are optimized through the use ofa polylactic acid (PLA) layer doped with a lipophilic diazeniumdiolated species that releases NO through a proton-driven mechanism. An Elast-Eon E2As polyurethane coating is used to both moderate NO release from the sensor surface and increase the sensor's linear detection range toward glucose. These sensors were evaluated for thromboresistance and in vivo glucose performance through implantation in rabbit veins. By maintaining NO flux on a similar scale to endogenous endothelial cells, implanted glucose sensors exhibited reduced surface clot formation which enables more accurate quantitative glucose measurements continuously. An in vivo time trace of implanted venous sensors demonstrated glucose values that correlated well with the discrete measurements of blood samples on a benchtop point-of-care sensor-based instrument. The raw measured currents from the implanted glucose sensors over 7 h time periods were converted to glucose concentration through use of both a one-point in vivo calibration and a calibration curve obtained in vitro within a bovine serum solution. Control sensors, assembled without NO release functionality, exhibit distinctive surface clotting over the 7 h in vivo implantation period.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2015年第4期464-468,共5页 中国化学快报(英文版)
关键词 Nitric oxide release coatingsGlucose sensorsPolylactic acid layerQuantitative glucose measurements Nitric oxide release coatingsGlucose sensorsPolylactic acid layerQuantitative glucose measurements
  • 相关文献

参考文献14

  • 1M.S. Boyne, D.M. Silver, J. Kaplan, C.D. Saudek, Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor, Diabetes 52 (2003) 2?90-2?94.
  • 2N. Wisniewski, M. Reichert, Methods for reducing biosensor membrane biofoul- ing, Colloid Sure B: Biointerfaces 18 (2000) 197-219.
  • 3M. Frost, M.E. Meyerhoff, In vivo chemical sensors: tackling biocompatibility, Anal. Chem. 78 (2006) 7370-7377.
  • 4M.W. Vaugho, L Kuo, J.C. Liao, Estimation of nitric oxide production and reaction rates in tissue by use of a mathematical model, Am. J. Physiol. 274 (1998) H2163-H2176.
  • 5Q. Yan, T.C. Major, R.H. Bartlett, M.E. Meyerhoff, lntravascular glucose[lactate sensors prepared with nitric oxide releasing poly (lactide-co-glycolide)-based coatings for enhanced biocompatibility, Biosens. Bioelectron. 26 (2011) 42?0-4282.
  • 6Q. Yah, g. Peng, S. Gang, et al., Measurement of tear glucose levels with ampero- metric glucose biosensor/capillary tube configuration, Anal. Chem, 83 (2011) 8341-8346.
  • 7M.M. Batchelor, S.L. Reoma, P.S. Fleser, et al., More lipophilic dialkyldiamine- based diazeniumdiolates: synthesis, characterization, and application in prepar- ing thromboresistant nitric oxide release polymeric coatings, J. Med. Chem. 46 (2003) 5153-5161.
  • 8D.S. Bindra, Y.N. Zhang, G.S. Wilson, et al., Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring, Anal. Chem. 63 (1991) 1692-1696.
  • 9R. Gifford, M.M. Batchelor, Y. Lee, et al., Mediation of in vivo glucose sensor inflammatory response via nitric oxide release, J. Biomed. Mater. Res. A 75A (2005) 755-766.
  • 10I. Carelli, 1. Chiarotto, 1. Curulli, G. Palleschi, Electropolymerization of hydroxy- benzene and aminobenzene isomers on platinum electrodes to assemble inter- ference-free electrochemical biosensors, Electrochim. Acta 41 (1996) 1793-1800.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部