摘要
在分析油田配电网特性的基础上,提出了结合传统投切电容补偿和新型静止无功发生器(SVG)技术相结合的混合式动态无功补偿装置方案,并根据新疆油田公司百口泉采油厂的使用案例进行了分析,证明变压器下混合式动态无功补偿装置是油田合理的无功补偿方案,可将变压器出线端的功率因数提高到0.98以上。
Based on the characteristics analysis of oilfield distribution network, this paper presents the scheme for hybrid dynamic reactive power compensation device combined with the traditional capacitor switching compensation and SVG technology. The case study of Baikouquan Oil Plant, Xinjiang Oilfield Company, proves that the transformerrs hybrid dynamic reactive power compensation device is reasonable reactive power com- pensation scheme for oilfield, which can improve the power factor on the transformer outlet side to more than 0.98.
出处
《电力与能源》
2015年第2期265-267,共3页
Power & Energy
关键词
抽油机
功率因数
无功补偿
静态无功补偿
混合式动态无功补偿
oil pumping unit
power factor
reactive power compensation
static reactive power compensation
hybrid dynamic reactive power compensation