摘要 以华电国际邹县发电厂#7机组为例,对给水采用全挥发处理和加氧处理情况进行跟踪对比,通过水汽品质、水冷壁沉积量及给水系统压降等变化,说明超超临界直流炉机组给水加氧处理是更安全、经济的运行方式。 Taking the unit No. 7 of Zhouxian Power Plant as example,the situation of feedwater treatment by all volatile treatment technology and oxygenation treatment technology was traced. Based on comparison of the water steam quality,the deposition on the water wall and the pressure losses of feedwater system,it was shown that the oxygenation treatment is more safe and economical operation mode for ultra supercritical oncethrough boiler unit.
出处 《华电技术》 CAS 2015年第4期52-54,78,共3页 HUADIAN TECHNOLOGY
关键词 1 000 MW机组 超超临界机组 加氧处理 给水 1 000 MW unit ultra supercritical unit all volatile treatment oxygenation treatment feedwater
  • 相关文献

参考文献3

  • 1DL/T805.1-2002火电厂汽水化学导则第1部分:直流锅炉给水加氧处理导则[S].
  • 2陈裕忠,黄万启.1000MW超超临界机组给水加氧三年实践效果分析与评价[c]//中国电厂化学专业委员会2013年年会暨学术研讨会论文集.长沙:中国电机工程学会火电分会电厂化学专业委员,2013.
  • 3李志刚,陈戎.火电厂锅炉给水加氧处理技术研究[J].中国电力,2004,37(11):47-52. 被引量:43

二级参考文献7

  • 1DL/T805.1-2002,火电厂汽水化学导则第一部分:直流锅炉给水加氧处理导则[S].
  • 2VGB-R450Le 1988, VGB Guidelines for Boiler Feedwater, Boiler Water,Steam of Steam Generators with A Permissible Operating Pressure >68 ba[S ].
  • 3T H McCloskey, R B Dooley, W P McNaughton. Turbine Steam Path Damage: Theory and Practice [ M ].EPRI, 1999.
  • 4ПA阿科利津.热能动力设备金属的腐蚀与保护[M].北京:水利电力出版社,1988.
  • 5UREvans.金属的腐蚀与氧化[M].北京:机械工业出版社,1976.
  • 6G M W MANN, R GRANSEY. Waterside corrosion associated with two shift boiler operation on all volatile treatment chemistry [ J ].Materials Performance, 1980.
  • 7火电厂蒸汽通流部件高温氧化皮的影响与防治对策研讨会论文集[C].中国电机工程学会火电分会,2002.

共引文献42