结合无功补偿原理以及矿热炉无功功率产生的原因,综合阐述了无功功率对产量的影响,以及国内外现有几种补偿方式的原理及应用情况,为铁合金生产企业选择补偿方式提供了意见性参考。
Combined with the theory of reactive power compensation and the cause of reactive power in submerged arc fur-nace, this paper expounds the effects of reactive power on the output and the theory and applications of compensation methods at home and aboard. And this paper provides reference for ferroalloy enterprise in selecting compensation method.