摘要
利用FLUENT软件,采用功率替代温度的优化方法计算出气流式水平姿态传感器密闭腔体内的温度分布图,分别计算了传感器在不同倾角状态下和不同环境温度下密闭腔体内的温度场分布情况,计算和实验结果表明:气流式水平姿态传感器的两热敏电阻丝的温度差与倾角有很好的线性关系,它们之间的变化率为2.618 3 K/(o);环境温度对传感器的两热敏电阻丝的温度差的影响也是有线性关系的,倾角为24o时它们之间的变化率为–0.135 9K/K,与实验结果有很好的相似度。
Optimization method of power replacing temperature was used to calculate the temperature distribution of the airflow level posture sensor in closed cavity. The temperature distribution of sensor in closed cavity was calculated at different inclination sensor status and under different environmental temperatures. The calculation and experimental results show that the temperature difference between two thermal resistance wires of airflow level posture sensor has good linear relationship with inclination, and the change rate is 2.618 3 K/(~). The effection of environmental temperature on the resistance difference about the sensors' two thermal resistance wires also has a linear relationship. When the inclination is 24~, the change rate is -0.135 9 K/K. It has a good similarity with the experimental results.
出处
《电子元件与材料》
CAS
CSCD
2015年第6期41-43,共3页
Electronic Components And Materials
基金
国家自然科学基金资助(No.60772012)
北京市自然科学基金重点项目&北京市教委科技计划重点项目资助(No.KZ201511232034)
新世纪优秀人才支持计划(NCET)资助
北京市重点实验室开放课题资助
北京市新世纪百千万人才工程培养资助项目
现代测控技术教育部重点实验室资助
北京信息科技大学大学生科技创新计划资助
北京信息科技大学研究生科技创新项目资助
关键词
FLUENT
气流式水平姿态传感器
倾角
环境温度
热源功率
温度差
Fluent
airflow level posture sensor
inclination
environmental temperature
power of hot source
temperature difference