摘要 目的:研究设计频域磁声耦合成像系统,以实现组织样本的电导率成像。方法:采用连续波正弦信号激励产生磁声信号,利用锁相放大器进行磁声信号的频域幅值和相位的检测,设计基于虚拟仪器的磁声成像实验系统控制程序,进行金属模型的磁声信号实验验证。结果:设计的频域磁声成像实验系统信号幅值检测精度明显提高,达到10-7Pa,实现了磁声信号声源的空间定位,定位精度达到mm级。结论:设计的频域磁声耦合成像系统实现了低频激励下高分辨率声源定位,对于磁声耦合声源理论的研究以及提高磁声成像的精度具有重要意义。 Objective To design a new frequency domain magnato-aoustic imaging system to image the conductivity of medium. Methods A continuous sine wave signal was adopted to stimulate the MAT signal. The lock-in technique was applied to measuring the amplitude and phase of the magneto-acoustic signal. The drive control program of the imaging system was designed using virtual instrument tools. The experiments were conducted on the phantom made of coper wire.Results The amplitude precision was improved up to 10-7Pa, while the system could locate the sonic source with locating precision of millimeter. Conclusion A new magneto-acoustic imaging system is proposed with high locating precision as well as low frequency excitation, which is significative to the study on the sonic source theory and improvement of the imaging precision.
出处 《医疗卫生装备》 CAS 2015年第5期1-5,共5页 Chinese Medical Equipment Journal
基金 国家自然科学基金重点项目(51137004) 国家自然科学基金面上项目(81171424) 天津应用基础与前沿技术青年项目(13JCQNJC14000)
关键词 磁声耦合成像 频域 实验系统 锁相放大 magneto-acoustic imaging frequency domain experiment system lock-in amplification
  • 相关文献

参考文献16

  • 1Alexander S, Aviram N,Zabava G,et a/. Electrical impedance scan- ning for the early detection of breast cancer in young women : prelim- inary results of a multicenter prospective clinical trial[J]. Journal of Clinical Oncology, 2005,23 (12) : 2 703-2 715.
  • 2Gabriel S, Lan R W, Gabriel C. The dielectric properties of biological tissues II :measurements on the frequency range 10 Hz to 20 GHz[J]. Phys Med Biol, 1996,41 ( 11 ) : 2 251-2 269.
  • 3杨琳,徐灿华,史学涛,付峰,代萌,夏军营,李靖,董秀珍.一种基于多频电阻抗断层成像系统的校准方法研究[J].医疗卫生装备,2014,35(1):1-5. 被引量:2
  • 4Bradley J R,Peter J B. A theoretical model for magneto-acoustic imaging of bioelectric currents[J]. IEEE Transactions on Biomedical Engineering, 1994,41 ( 8 ) : 723 -728.
  • 5HAN Wen. Volumetric Hall Effect tomographyc[J]. Ultrason Imaging, 1999,21:186-200.
  • 6Bradley J R. The role of magnetic forces in biology and medicine [J]. Experimental Biology and Medicine, 2011,236 : 132-137.
  • 7XIA Rong-min, LI Xu, HE Bin. Reconstruction of vectorial acoustic sources in time-domain tomography[J]. IEEE Trans Med Imaging, 2009,28 (5) : 669-675.
  • 8HU Gang, HE Bin. Magnetoacoustic imaging of magnetic iron oxide nanoparticles embedded in biological tissues with microsecond mag- netic stimulation[J]. Anolied Phvsics Letters. 2012.100:013 704.
  • 9XU Yuan,HE Bin. Magnetoacoustic tomography with magnetic in- duction (MAT-MI) [J]. Institute of Physics Publishing,2005,50 : 5 175-5 187.
  • 10Leo M,HU Gang,HE Bin. Magnetoacoustic tomography with mag- netic induction for high-resolution bioimepedance imaging through vector source reconstruction under the static field of MRI magnet[J]. Medical Physics ,2014,41:022 902.

二级参考文献9

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部