期刊文献+

注射用复合维生素中草酸的HPLC法测定 被引量:2

Determination of oxalic acid in vitamin complex injection by HPLC
下载PDF
导出
摘要 建立了高效液相色谱法测定注射用复合维生素中残留草酸的方法.采用Phenomenex Rezex ROA-Organic acid 3.7 mm×150 mm的强阳离子交换柱(H+型),紫外检测器,以0.01 mol/L的硫酸为流动相.结果显示:在选定的色谱条件下,草酸的线性良好,回收率为98.1%~100.4%.所测试的3批样品中均未检出草酸. A method for contents determination of oxalic acid in Vitamin complex injection by HPLC was built. The experimental conditions were Phenomenex Rezex ROA-Organic acid 3.7 mm × 150 mm (H+) column, UV wavlength was 210 nm, injection volumn was 20μL, column temperature was 60℃ and mobile phase was 0.01 mol/L H2SO4. The results indicated that the linearity was good. The average recovery was 98.1%--100.4%. Detection of three batches of Vitamin complex injection were used the es- tablished method, and the results were not detected oxalic acid.
出处 《河北大学学报(自然科学版)》 CAS 北大核心 2015年第3期253-257,共5页 Journal of Hebei University(Natural Science Edition)
基金 国家自然科学基金资助项目(21102032)
关键词 注射用复合维生素 草酸 高效液相色谱 vitamin complex injection oxalic acid HPLC