期刊文献+

静压差法在GAF型通风机风量测试中的应用 被引量:5

Application of Static Differential Pressure Method for Flow Rate Measurement of GAF Fan
下载PDF
导出
摘要 风量是煤矿主要通风机性能的关键技术指标之一,也是煤矿日常通风管理的重要参数。提出了静压差法测试煤矿GAF型主要通风机风量的方法,介绍了静压差法测试方法的原理和关键量测试的注意事项,并验证了静压差法测试结果的可靠性。 The flow rate is one of the critical technology index for main fan performance of coal mine, and it is also an important parame- ter of daily ventilate management in coal mine. In this paper, static differential pressure method for measurement of GAF fan flow rate in coal mine was proposed. The mechanism of static differential pressure method and some notes for measurement of pivotal value were in- troduced,and the reliability of the testing result for static differential pressure method was also verified.
作者 陈刚
出处 《中州煤炭》 2015年第5期27-29,共3页 Zhongzhou Coal
关键词 风量 静压差法 GAF型通风机 主要通风机 flow rate static differential pressure method GAF main fan main fan
  • 相关文献

参考文献5

二级参考文献4

共引文献59

同被引文献26

引证文献5

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部