摘要 通常脉搏传导时间PTT(pulse transit time)可以作为衡量动脉将硬度的指标,而且它现在也可以被用作估计血压的一种方式[1]。利用Matlab软件分析Physio Net数据库随机5个患者连续一个小时数据进行分析,研究连续有创收缩压同PTT的关系。经过数据的分析,PTT和收缩压有很好的线性相关性,可以作为血压测量的一种方法。利用均值优化法可以增加测量的准确度,选择脉搏波波谷作为特征点的PTT和收缩压有更好的相关性。 Typically pulse transit time (PTT) can be used as a measure of the arterial stiffness index, and it can now also be used as a way to assess blood pressure. Using Matlab software database analyze PhysioNet five random patients consecutive one hour data, research continuous invasive systolic relationship with the PTT. After analyzing the data, PTT and systolic blood pressure has a good linear correlation can be used as a method of blood pressure measurement. Mean optimization method can increase the use of measurement accuracy, choose the pulse wave valley as feature points of PTT and systolic blood pressure have a better correlation.
出处 《电脑与信息技术》 2015年第3期34-36,共3页 Computer and Information Technology
基金 辽宁省自然科学基金(项目编号:201102289) 沈阳市科技专项资金(项目编号:F12-193-9-12)
关键词 脉搏传导时间 MIMIC数据库 有创收缩压 血压测量 pulse transit time MIMIC database invasive systolic blood pressure blood pressure measurement
  • 相关文献

参考文献9

  • 1C. Ahlstrom, A. Johansson, T. L. F. Uhlin, and P. Ask. Nonin- vasive investigation of blood pressure changes using the pulse wave transit time: a novel approach in the monitoring of hemodialysis patients[J]. The Japanese Society for Artificial Or- gans,vol. 8, pp. 192-197, 2005.
  • 2T. Ma and Y. T. Zhang. A correlation study on the variabilities in pulse transit time, blood pressure, and heart rate recorded si- multaneously from healthy subjects [C]. in Proceeding of the 27th Annual Conference of the IEEE Engineering in Medicine and Biology, Shanghai, China, 2005, pp. 996-999.
  • 3P. A. Obrist, K. C. Light, J. A. McCubbin, J. S. Hutcheson, and J. L. Hoffer. Pulse transit time: relationship to blood pressure and myocardial performance [J]. Psychophysiology, vol. 16, no. 3, pp. 292-301, 1979.
  • 4J. D. Lane, L. Greenstadt, D. Shapiro, and E. Rubinstein. Pulse transit time and blood pressure: an intensive analysis [J]. Psy- chophysiology, vol. 20, no. 1, pp. 45-49, 1983.
  • 5S. H. Shin, Y. B. Park, H. W. Rhim, W. S. Yoo, Y. J. Park, and D. H. Park. Muhibody dynamics in arterial system [J]. Journal of Mechanical Science and Technology, vol. 19, no. 1, pp. 343-349, 2005.
  • 6M. Nitzan, B. Khanokh, and Y. Slovik. The difference in pulse transit time to the toe and finger measured by photoplethysmog- raphy[J]. Physiological Measurement, vol. 23, pp. 85-93, 2002.
  • 7X. F. Teng and Y. T. Zhang. Theoretical study on the effect of sensor contact force on pulse transit time[J]. IEEE Transactions on Biomedical Engineering, vol. 54, no. 8, pp. 1490-1498, Au- gust 2007.
  • 8C. C. Y. Poon and Y. T. Zhang. Using the changes in hydrostat- ic pressure and pulse transit time to measure arterial blood pressure [J]. in Proceedings of the 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Lyon, France, August 23-26 2007, pp. 2336-2337.
  • 9W. Chen, T. Kobayashi, S. Lchikawa, Y. Takeuchi, and T. To- gawa. Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration [J]. Medical and Biological Engineering and Computing, vol. 38, pp. 569-574, 2000.

同被引文献9

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部