期刊文献+

DynaCT Cardiac技术在三维旋转左心房成像实时三维重建中的应用 被引量:1

Utility of DynaCT cardiac technique in three-dimensional rotational angiogram of left atrium during ablation of atrial fibrillation
下载PDF
导出
摘要 目的探讨Artis zeego Card血管机DynaCT Cardiac技术在房颤射频消融术中三维旋转左心房造影实时三维重建左心房中的临床应用。方法 62例房颤行射频消融患者,导管室内消融术中行三维旋转左心房造影实时三维重建左心房,将实时心脏透视与一键切割分离出的三维左心房实时叠加并引导消融导管定位。结果所有患者均顺利完成三维旋转左心房造影实时三维重建,无不良反应发生。获得患者当前左心房解剖细节叠加融合在透视影像中,利于导向术中消融导管的精确定位。结论 DynaCT Cardiac技术在三维旋转左心房造影实时三维重建中是安全、有效的,此项技术展示出良好的实用性和临床应用前景。 Objective To study the utility of DynaCT cardiac technique of Artis zeego card digital subtraction an‐giography in rotational angiogram and three‐dimensional model reconstruction of left atrium during atrial fibrillation (AF) ablation .Method Sixty‐two patients undergoing AF ablation were included in this study .Reconstructing three‐dimensional rotational angiogram (3DRA) of left atrium were performed in all the patients .The 3D model of left a‐trium was reconstructed and registered with the live fluoroscopy synchronously .In the navigation of the registered 3DRA and CARTO system ,the ablation of AF was performed .Result The 3DRA and 3D model reconstruction of left atrium were performed successfully in all patients and registered with the live fluoroscopy ,which was benefited to AF ablation .No adverse reaction occurred during the procedure .Conclusion DynaCT cardiac technique is safe and effective applying to the 3DRA and 3D model reconstruction of left atrium during ablation of AF ablation .The tech‐nology show s good practicability and clinical application prospects .
出处 《贵州医药》 CAS 2015年第2期110-112,共3页 Guizhou Medical Journal
基金 贵州省科技支撑计划项目[黔科合SY字(2012)3108号]
关键词 房颤 消融 三维重建 造影 Atrial fibrillation Ablation Three-dimensional reconstructionv Radiography
  • 相关文献

参考文献5

  • 1周自强,胡大一,陈捷,张仁汉,李奎宝,赵秀丽.中国心房颤动现状的流行病学研究[J].中华内科杂志,2004,43(7):491-494. 被引量:1399
  • 2Orlov MV,Hoffmeister P,Chaudhry GM,et al.Threedimensional rotational angiography of the left atrium and esophagus-A virtual computed tomography scan in the electrophysiology lab[J]?Heart Rhythm,2007,4(1):37-43.
  • 3Thiagalingam A,Manzke R,D'Avila A,et al.Intraprocedural volume imaging of the left atrium and pulmonary veins with rotational X-ray angiography:implications for catheter ablation of atrial fibrillation[J].J Cardiovasc Electrophysiol,2008,19(3):293-300.
  • 4唐闽,李劲宏,黄从新.左房造影旋转成像实时三维重建左房图像技术[J].中国心脏起搏与心电生理杂志,2009,23(1):79-80. 被引量:5
  • 5Zhong H,Lacomis JM,Schwartzman D.On the accuracy of CartoMerge for guiding posterior left atrial ablation in man[J].Heart Rhythm,2007,4(5):595-602.

二级参考文献4

  • 1Hoit DA, Malek AM. Three-dimensional rotational angiographic detection of in-stent stenosis in wide-necked aneurysms treated with a self-expanding intracranial stent [ J ]. Neurosurgery, 2005,57 (6) : 1 228
  • 2Orlov MV, Hoffmeister P, Chaudhry GM, et al. Three-dimensional rotational angiography of the left atrium and esophagus-A virtual computed tomography scan in the electrophysiology lab [ J ] ? Heart Rhythm, 2007, 4( 1 ) : 37
  • 3Thiagalingam A, Manzke R, D'Avila A, et al. Intraprocedural volume imaging of the left atrium and pulmonary veins with rotational X- ray angiography : implications for catheter ablation of atrial fibrillation [ J ]. J Cardiovasc Electrophysiol, 2008,19 (3) : 293
  • 4胡大一,孙艺红,周自强,李奎宝,倪永斌,杨光,孙淑红,李蕾.中国人非瓣膜性心房颤动脑卒中危险因素的病例-对照研究[J].中华内科杂志,2003,42(3):157-161. 被引量:360

共引文献1402

同被引文献8

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部