摘要 目的比较使用GenesisⅡ高屈曲假体和普通假体行全膝关节置换术(TKA)的患者术后早期疗效,研究高屈曲假体能否增加术后活动度。方法对2007年9月-2011年12月初次行TKA的80例患者(85膝)进行随访,最终符合标准且获得随访60例(60膝),随访时间2~4年,平均2.7年。其中32例使用GenesisⅡ高屈曲假体(美国Smith&Nephew公司),28例使用普通假体,比较术后活动度、美国特种外科医院(HSS)评分及并发症有无差别。结果高屈曲假体组与普通假体组末次随访时的膝关节活动度分别为(112.8±11.0)、(108.9±12.1)°,HSS评分分别为(86.6±11.9)、(84.2±13.3)分,股骨后髁偏心距分别为(25.1±7.3)、(24.5±6.2)mm,差异均无统计学意义(P〉0.05)。截至末次随访时,两组均无患者因松动、骨溶解或其他原因翻修。结论高屈曲膝关节假体并不增加术后活动度,尚需中长期随访研究高屈曲膝关节假体能否真正提高膝关节活动度,且不增加相应的并发症。 Objective To compare the early clinical outcome of Genesis Ⅱ high-flexion versus standard prostheses in total knee arthroplasty(TKA), and evaluate whether high-flexion prostheses can improve the postoperative range of motion(ROM). Methods Between September 2007 and December 2011, 80 patients(85 knees) consecutively underwent posterior cruciate-sacrificing TKA with Genesis Ⅱ systems. Finally, we reviewed 60 patients(60 knees) including 32 knees in high-l exion group and 28 knees in standard group. The follow-up time was 2.7 years in average. The postoperative knee ROM and the rate of complication of the two groups were evaluated. Results The mean postoperative knee ROM of 32 knees was 112.8° in the high-flexion group and was 108.9° in the standard group. The mean postoperative HSS score was 86.6 and 84.2, respectively. The postoperative knee ROM, hospital for special surgery(HSS) score and the rate of complication did not show signii cant dif erence between the two groups. Conclusions The high-l exion prosthesis is no better than the ordinary prosthesis in terms of the range of motion. We need more mid to long-term studies to do further research.
出处 《华西医学》 CAS 2015年第5期869-872,共4页 West China Medical Journal
关键词 全膝关节置换术 高屈曲膝假体 疗效 Total knee arthroplasty High-flexion prostheses Curative effect
  • 相关文献

参考文献18

  • 1Banks S, Bellemans J, Nozaki H, et al. Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties[J]. Clin Orthop Relat Res, 2003(410): 131-138.
  • 2曾羿,沈彬.高屈曲度膝关节假体实现高屈曲了吗?[J].中国骨与关节外科,2013,6(1):80-82. 被引量:3
  • 3Hanratty BM, Thompson NW, Wilson RK, et al. The influence of posterior condylar offset on knee flexion after total knee replacement using a cruciate-sacrificing mobile-bearing implant[J]. J Bone Joint Surg Br, 2007, 89(7): 915-918.
  • 4Ewald FC. 3he knee society total knee arthroplasty roentgenographic evaluation and scoring system[J]. Clin Orthop Relat Res, 1989(248): 9-12.
  • 5Gomes LS, Bechtold ]E, Gusti|o RB. Pate|lar prosthesis positioning in total knee arthroplasty. A roentgenographic study[J]. Clin Orthop Relat Res, 1988(236): 72-81.
  • 6曾勉东,杨波,谢景开,吕玉明,尹彪.影响全膝关节置换术后关节活动度的相关因素分析[J].中国骨与关节损伤杂志,2012,27(10):887-889. 被引量:12
  • 7Suggs JF, Kwon YM, Durbhakula SM, et al. In vivo flexion and kinematics of the knee after TKA: comparison of a conventional and a high flexion cruciate-retaining TKA design[J]. Knee Surg Sports Traumatol Arthrosc, 2009, 17(2): 150-156.
  • 8Malik A, Salas A, Ben Ari J, et aI. Range of motion and function are similar in patients undergoing TKA with posterior stabilised and high-flexion inserts[J]. Int Orthop, 2010, 34(7): 965-972.
  • 9Seon JK, Park SJ, Lee KB, et al. Range of motion in total knee arthroplasty: a prospective comparison of high-flexion and standard cruciate-retaining designs[J]. J Bone Joint Surg Am, 2009, 91(3): 672-679.
  • 10Minoda Y, Aihara M, Sakawa A, et al. Range of motion of standard and high-flexion cruciate retaining total knee prostheses[J]. ] Arthroplasty, 2009, 24(5): 674-680.

二级参考文献75

  • 1沈灏,张先龙,蒋垚,邵俊杰,陈炀,宋文奇.NexGen LPS-Flex人工全膝置换术的技术特点和初步疗效[J].上海交通大学学报(医学版),2006,26(2):124-127. 被引量:3
  • 2Huddleston JI,Scarborough DM,Goldvasser D,et al.2009 Marshall Urist Young Investigator Award:how often do patients with high-flex total knee arthroplasty use high flexion? Clin Orthop Relat Res,2009,467(7):1898-1906.
  • 3Ranawat CS.Design may be counterproductive for optimizing flexion after TKR.Clin Orthop Relat Res,2003(416):174-176.
  • 4Han HS,Kang SB,Yoon KS.High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement.J Bone Joint Surg (Br),2007,89(11):1457-1461.
  • 5Akagi M,Nakmura T,Matsusue Y,et al.The Bisurface total knee replacement:a unique design for flexion:four-to-nine-year follow-up study.J Bone Joint Surg (Am),2000,82(11):1626-1633.
  • 6Laubenthal KN,Smidt GL,Kettelkamp DB.A quantitative analysis of knee motion during activities of daily living.Phys Ther,1972,52(1):34-43.
  • 7Ritter MA,Harty LD,Davis KE,et al.Predicting range of motion after total knee arthroplasty.Clustering,log-linear regression,and regression tree analysis.J Bone Joint Surg (Am),2003,85(7):1278-1285.
  • 8Anouchi YS,MeShane M,Kelly F Jr.Range of motion in total knee replacement.Clin Orthop Relat Res,1996(331):87-92.
  • 9Schunnan DJ,Rojer DE.Total knee arthroplasty:range of motion across five systems.Clin Orthop Relat Res,2005(430):132-137.
  • 10Argenson JN,Komistek RD,Mahfouz M,et al.A high flexion total knee arthroplasty design replicates healthy knee motion.Clin Orthop Relat Res,2004(428):174-179.

共引文献17

同被引文献16

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部