双变形镜人眼视网膜高分辨率显微成像系统 被引量:8

High-Resolution Retinal Imaging System with Dual Deformable Mirrors
原文传递
导出
摘要 如何有效校正随人群起伏很大的人眼像差,提高视网膜高分辨率成像技术的人群适用范围是临床应用面临的最大难题。现有的单一波前校正器无法同时清除高阶和低阶视觉像差。针对人眼高阶像差校正需求,研制成功了169单元3 mm极间距分立式压电变形镜,并与大行程Bimorph变形镜组合,建立了一套双变形镜的人眼视网膜成像系统。系统可实现对离焦小于±4.5 D、散光小于±3.0 D的低阶像差及前8阶Zernike像差的有效校正,极大地提高了系统的人群适用范围和成像质量。以低阶像差大小作为入选标准,进行小样本量人眼视网膜成像实验,获得了近衍射极限的视网膜图像。该系统适用范围明确,便于后续临床应用。 How to effectively correct ocular aberrations which vary fast from person to person and improve the application scope of adaptive optics retinal imaging system is the biggest problem in clinical application. It is difficult for a single corrector to compensate both low order and high order ocular aberrations simultaneously. Due to the correction requirements of high order aberrations, a 169-element discrete piezoelectric deformable mirror with3 millimeters spacing is successfully developed. Combined with a large stroke bimorph mirror, a retinal imaging system with two deformable mirrors is developed. The system can compensate low order aberrations up to ±4.5diopters of defocus and ±3 diopters of cylindrical. High order Zernike aberrations up to the 8th order can also be corrected by this system. Both imaging quality and application scope are significantly improved. Taking the size of low order aberrations as inclusion criteria, a little sample is tested by the human retinal imaging experiment, and near diffraction-limited retinal images are achieved. The system has a clear application scope, which is convenient for future clinical application.
出处 《光学学报》 EI CAS CSCD 北大核心 2015年第5期29-36,共8页 Acta Optica Sinica
基金 国家自然科学基金(61378064 61205202) 国家重大仪器专项(2012YQ120080)
关键词 自适应光学 变形镜 人眼像差 视网膜成像 adaptive optics deformable mirrors eye aberration retinal imaging
  • 相关文献

参考文献14

  • 1Liang J, Williams D R, Miller D T. Supernormal vision and high-resolution retinal imaging through adaptive optics[J]. J Opt Soe Am A, 1997. 14(I 1): 2884-2892.
  • 2Williams D R. Imaging single cells in the living retina[J]. Vision Research, 2011,51(13): 1379-1396.
  • 3Thibos I~ N, Hong X, Bradley A, et al.. Statistieal variation of aberralion structure and image quality heahhy eyes[J]. J Opt Soc Am A, 2002, 19(12): 2329-2348.
  • 4凌宁,张雨东,饶学军,李新阳,王成,胡弈云,姜文汉.用于活体人眼视网膜观察的自适应光学成像系统[J].光学学报,2004,24(9):1153-1158. 被引量:45
  • 5Niu S, Shen .l, Liang C, et al.. High-resolution retinal imaging with micro adaptive optics system[J]. Applied Optics, 201 l, 50(22): 4365-4375.
  • 6周虹,官春林,戴云.用于自适应光学视网膜成像系统的双压电片变形反射镜[J].光学学报,2013,33(2):70-75. 被引量:13
  • 7孔宁宁,李大禹,夏明亮,齐岳,宣丽.开环双脉冲液晶自适应光学视网膜成像系统[J].光学学报,2012,32(1):90-98. 被引量:15
  • 8Dalimier E, Dainty C, Barbur J I,. Effects of higher-order aberrations on contrast acuity as a function of light level[J]. Jourual of Modern Optics, 2008, 55(4-5): 791-803.
  • 9Chen D C, Jones S M, Silva D A, et al.. High-resolution adaptive optics scanning laser ophthalmoscope with dual deformable mirrors[J]. J Opt Soc Am A, 2007, 24(5): 1305-1312.
  • 10Cense B, Gao W, Brown J M, et al.. Retinal imaging with polarization-sensitive optical coherence tomography and adaptive optics[J]. Optics Express, 2009, 17(24): 21634-21651.

二级参考文献59

  • 1凌宁,张雨东,饶学军,李新阳,王成,胡弈云,姜文汉.用于活体人眼视网膜观察的自适应光学成像系统[J].光学学报,2004,24(9):1153-1158. 被引量:45
  • 2凌宁,张雨东,饶学军,王成,胡羿云,姜文汉.High resolution mosaic image of capillaries in human retina by adaptive optics[J].Chinese Optics Letters,2005,3(4):225-226. 被引量:6
  • 3R. S. Jonnal, J. R. Besecker, J. C. Derbyetal.. Imaging outer segment renewal in living human cone photoreceptors[J]. Opt. Express, 2010, 18(5): 5257-5270.
  • 4S. V. Steffen, F. Monika, H. P. N. Scholl a al.. Fundus autofluorescence and progression of age related macular degeneration[J]. Survey of Ophthalmology, 2009, S4 (1): 96-117.
  • 5L J. Liang, B. Grimm, S. Goelzet al.. Objective measurement of wave aberrations of the human eye with the use of a Hartmann- Shack wave-front sensor[J]. J. Opt. Soc. Am. A, 1994, 11(7) : 1949-1957.
  • 6J. Liang, D. R. Williams, D. T. Miller. Supernormal vision and high-resolution retinal imaging through adaptive optics [J]. J. Opt. Soc. Am. A, 1997, 14(11): 2884-2892.
  • 7A. Roorda, F. Romero-Borja, W. J. Donnellyet al.. Adaptive optics scanning laser ophthalmoscopy[J]. Opt. Express, 2002, 10(9) : 405-412.
  • 8P. Prieto, E. Ferndez, S. Manzanera et al.. Adaptive optics with a programmable phase modulator: applications in the human eye[J]. Opt. Express, 2004, 12(17):4059-4071.
  • 9D. U. Bartsch, L. J. Zhu, P. C. Sun et al.. Retinal imaging with a low-cost micromaehined membrane deformable mirror[J]. J. Biomed. Opt., 2002, 7(3): 451-456.
  • 10Y. Liu, Z. Cao, D. Li et al.. Correction for large aberration with phase-only liquid-crystal wavefront corrector [J]. Opt. Engng. , 2006, 45(12) :128001.

共引文献60

同被引文献56

引证文献8

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部