过氧化氢与含氯消毒剂对口腔综合治疗台水消毒效果与污染状况调查 被引量:7

Investigation on contamination status and disinfection effect of hydrogen peroxide and chlorine disinfectant of dental unit waterline
原文传递
导出
摘要 目的观察含氯消毒剂对医疗机构口腔综合治疗台水消毒效果及口腔治疗用水污染状况。方法采用细菌定量检测和现场抽样调查方法,对扬州市医疗机构口腔综合治疗台用水污染状况及消毒效果进行检测与分析。结果共采集综合治疗台手机水和冲洗水各124份,细菌含量手机水中位值最高为1 521 cfu/ml,口腔冲洗水细菌含量中位值最高为586 cfu/ml。综合治疗台水每日用10 g/L过氧化氢消毒全管路一次,每周使用有效氯350 mg/L含氯消毒剂消毒全管路一次,对照组不做任何处理。对照组与实验组相比,手机水合格率分别由之前的20.97%提高到79.03%;冲洗水由53.23%提高到80.65%。结论扬州市医疗机构口腔综合治疗台水路污染情况严重,用含氯消毒剂等实施干预措施可以有效控制治疗台水路污染。 Objective To investigate the contamination status and disinfection effect of hydrogen peroxide and chlorine disinfectant of dental unit waterlines. Methods Bacteria quantitative detection and field sampling method were used to de- tect and analyze the contamination status and disinfection effect of hydrogen peroxide and chlorine disinfectant of dental unit waterlines in medical institutions. Results A total of 124 samples respectively of hand - piece water and dental washing water were collected. The maximum total - bacterial - count of hand - piece water and dental washing water were 1 521 cfu/ml and 586 cfu/ml respectively. Daily 10 g/L hydrogen peroxide and weekly 350 mg/L chlorine disinfectant were implemented in pipelines of dental units. No treatment was implemented in control group. Comparing the qualified rate of control group with experimental group,hand -piece water increased from 20. 97% to 79. 03% and dental washing water in- creased from 53.23% to 80. 65%. Conclusion Dental unit waterline contamination is serious in Yangzhou and can be controlled by chlorine disinfectant effectively.
出处 《中国消毒学杂志》 CAS 北大核心 2015年第6期545-546,549,共3页 Chinese Journal of Disinfection
关键词 口腔综合治疗台用水 细菌污染 含氯消毒剂 消毒效果 dental unit waterline microbial contamination chlorine disinfectant disinfection effect
  • 相关文献

参考文献6

二级参考文献20

  • 1.生活饮用水卫生规范[Z].[S].卫生部卫生法制与监督司,2001..
  • 2Meiller T F,Depada L G,Kelley J I,et al.Dental unit waterlines:biofilms,disinfection and recurrence[J].J Am Dent Assoc,1999,130(1):65-72.
  • 3Walker J T,Bradshaw D J,Fulford M R,et al.Microbiological evaluation of a range of disinfectant products to control mixed-species biofilm contamination in a laboratory model of a dental unit water system[J].Appl Environ Microbiol,2003,69(6):3327-3332.
  • 4Walker J T,Bradshaw D J,Finney M,et al.Microbiological evaluation of dental unit water systems in general dental practice in Europe[J].Eur J Oral Sci,2004,112(5):412-418.
  • 5Barbeau J,Gauthier C,Payment P.Biofilms,infectious agents,and dental unit waterlines:a review[J].Can J Microbiol,1998,44(11):1019-1028.
  • 6Kettering J D,Stephens J A,Munoz-Viveros C A,et al.Reducing bacterial counts in dental unit waterlines:tap water versus distilled water[J].J Contemp Dent Pract,2002,3(3):1-9.
  • 7Pederson E D,Stone M E,Ragain J C,et al.Waterline biofilm and the dental treatment facility:a review[J].Gen Dent,2002,50(2):190-195; quiz 196-197.
  • 8银燕,贾兴真,张聿为.辽宁省医疗机构消毒效果监测[J].中国消毒学杂志,2008,25(1):47-48. 被引量:32
  • 9乔玫,赵智敏,赵春兰.山西省医疗机构消毒效果监测结果分析[J].中国消毒学杂志,2008,25(1):49-51. 被引量:38
  • 10廖如燕,林锦炎,钟昱文,张里君.广东省32所医院胃肠镜污染与消毒现状调查[J].中国消毒学杂志,2008,25(1):51-53. 被引量:13

共引文献129

同被引文献78

引证文献7

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部