期刊文献+

铝板带加工厂防爆电气设计 被引量:1

Discussion on Explosion-proof Electrical Design in Aluminum Plate / Strip Processing Plant
下载PDF
导出
摘要 国家标准设计规范在电气防爆具体应用方面不够详细,尤其是防爆区域的划分存在很多争议。结合铝板带项目,从防爆区域划分、防爆电气设备选择、防爆电气施工与安装方面分析防爆电气设计,探讨设计和施工实践中存在的疑难争议问题及解决办法,以供工业建筑电气设计参考。 The applications of explosion-proof electrical design are not specified detailed enough in the national design standards.Many disputes still exist in the division of explosion-proof zone and the designers always do engineering work based on their own understanding of standards.Combining by aluminum plate,sheet and strip project as example, this paper analyzed the related explosion-proof design in aspects of the division of explosion-proof zone,selection of explosion-proof electrical equipment and the explosion-proof electrical construction and installation,and also discussed the existing disputed problems and solutions in the practice of design and construction.It could provide references for industry building electrical design.
作者 李骥
出处 《现代建筑电气》 2015年第5期41-44,共4页 Modern Architecture Electric
关键词 防爆区域 爆炸性气体环境 防爆电气设计 防爆电气设备 explosion-proof zone explosive gas environment explosion-proof electrical design explosion-proof electrical equipment
  • 相关文献

参考文献4

  • 1GB50058-2014爆炸危险环境电力装置设计规范[s].
  • 2GB50016-2014建筑设计防火规范[s].
  • 3GB50630-2010有色金属工程设计防火规范[s].
  • 494D401-3爆炸和火灾危险环境下电气线路和电气设备安装[G].