某机场工程复杂单元式幕墙性能试验研究 被引量:5

Performance Experimental Study on the Complicated Unitized Curtain Wall in Some Airport Project
下载PDF
导出
摘要 为验证某机场工程复杂单元式幕墙工程设计方案的可行性,研究复杂单元幕墙的各项性能指标,保证幕墙工程的适用性和安全性,采用1∶1比例单元板块模型对其进行了试验研究。试验中测试了幕墙的气密性、水密性、风荷载及地震作用下的变形性能、安全性能和软体撞击性能。特别对其进行了罕遇地震作用下的变形试验,并对试验结果进行分析,从而证明了幕墙设计方案是可行的。 In order to verify the design scheme feasibility of the complicated unitized curtain wall applied at an airport project and study its performances and guarantee the applicability and safety, the experimental model based on the design with 1 ∶ 1 size of the unit was built,and the air permeability,water tightness,deformation performance under wind load,earthquake and soft body impact were tested.Especially,the test under rare earthquake was made. The test results are analyzed to draw a conclusion that the design scheme is applicable.
出处 《施工技术》 CAS 北大核心 2015年第9期17-19,共3页 Construction Technology
基金 "十一五"国家科技支撑计划项目:建筑节能改造关键技术研究(2006BAJ01A03) 北京高等学校青年英才计划项目(YETP1819)
关键词 装饰装修 机场工程 单元式玻璃幕墙 性能 试验 decoration airports unitized curtain wall performance testing
  • 相关文献

参考文献7

  • 1ASTM Committee. ASTM E283 Curtain walling-air permeability -test method [ S ]. 2004.
  • 2ASTM Committee. ASTM E331 Curtain walling-static water resistance[ S ]. 2000.
  • 3ASTM Committee. ASTM E330 Curtain walling-resistance to wind load -test method [ S ]. 2002.
  • 4CWCT. Air, water and wind resistance [ S]. 2005.
  • 5AAMA. AAMA 501.4-00 Recommended static test method for evaluating curtain wall ( seismic inter story drift) [ S]. 2001.
  • 6CWCT. CWCT technical notes 75 impact performance of building envelopes: method for impact testing of cladding panels [S].2012.
  • 7CWCT. CWCT technical notes 76 impact performance of building envelopes: guidance on specification[ S]. 2012.

同被引文献11

引证文献5

二级引证文献11