摘要
详细分析了氯酸盐电解槽在操作时发生爆炸的现象和原因,同时,也提出了应采取的相应措施。
The phenomenon and the reason of chlorate electrolyzer explosion in operation was analyzed. At the same time, the corresponding measures were put forward.
出处
《现代盐化工》
2015年第3期19-21,共3页
Modern Salt and Chemical Industry
关键词
氯酸盐
电解槽
爆炸原因
chlorate
electrolytic cell
cause of the explosion