摘要
近年来现网移动通信基站陆续实施多种节能措施,引起基站负荷变化,基站供电系统亟需采取优化措施。通过分析南方某省会城市现网基站实际负荷数据,针对现网常见类型基站中存在的电源配置问题,提出了供电系统优化措施,从而在节约基站电源配套投资的同时,提高了基站通信电源系统的供电性能。
In recent years, all kinds of energy-saving measures have been implemented in mobile communication base station. Therefore, base station load has changed, so communication power supply system is being imperatively optimized. Through analyzing the actual load data of base station in some southern capital city, optimized measures are proposed concerning the power configuration in common base station. The communication power supply system performance of base station is improved, meanwhile, the investment of base station power supply system will be saving.
出处
《邮电设计技术》
2015年第5期89-92,共4页
Designing Techniques of Posts and Telecommunications
关键词
移动通信基站
基站负荷
电源系统优化
Mobile communication base station
Base station load
Power system optimization