期刊文献+

导航系统中坐标系转换的误差分析

Precision of positioning for the transformation of coordinates in navigation system
原文传递
导出
摘要 以对电磁系统不会产生干扰的试验框架作为参考系,以电磁导航为对象,进行数据测量和误差分析.通过绝对坐标和相对坐标的对比证明,在导航系统中相对坐标的方式会增大系统的误差. Based on the experimental framework whereby there is no interference with the electromagnetic system,and with the electromagnetic navigation as the object, this study measures the data and errors. The comparison between relative and absolute coordinates proves that the relative coordinates will increase the positioning error.
作者 马宝秋
出处 《石家庄职业技术学院学报》 2015年第2期30-32,共3页 Journal of Shijiazhuang College of Applied Technology
关键词 电磁导航 坐标转换 定位误差 参考坐标 electromagnetic navigation coordinate transformation positioning error reference coordinate
  • 相关文献

参考文献5

  • 1FALCONER A,FEGELMAN E J,NUSSBAUM M S,et al. A Prospective Comparison of Laparoscopic Ultrasound vs Intrao- perative Cholangiogram during Laparoscopic Cholecystectomy [J]. Surgical Endoscopy, 1999,13(8) :784-788.
  • 2俞亚青,田学隆,闫春红.医学图像配准方法分类及现状[J].重庆大学学报(自然科学版),2003,26(8):114-118. 被引量:13
  • 3BAO P,WARMATH J, GALLOWAY R, et al. Ultrasound-to- computer-tomography Registration for Image-guided Laparo-scopic Liver Surgery [J]. Surg Endosc,2005(19):424-429.
  • 4凌树森.试验数据的统计处理和误差分析 第六讲 误差分析(续)[J].理化检验(物理分册),2001,37(9):410-414. 被引量:2
  • 5WAGNER A, SCHICHO K, BIRKFELLNER W, et al. Quanti- tative Analysis of Factors Affecting Intraoperative Precision and Stability of Optoeleetronic and Electromagnetic Tracking Systems [J]. Med Phys,2002,29(5):905-912.

二级参考文献30

  • 1VAN DEN ELSEN P A,EVERT -JAN D POL, MAX A. Viergever. Medical image matching - a review with classification[J]. IEEE Engineering in Medicine and Biology Magazine, 1993, 12(1) : 26 - 39.
  • 2ANTOINE MAINTZ J B, MAX A. Viergever. A survey of medical image registration [ J ]. Medical Image Analysis,1998, 2(1) :1 -36.
  • 3REN HAI- PING, HU YANG, WU WEN -KAI , et al.Multi - resolution three - dimensional multi - modality image registration by maximization of mutual information[A] : Engineering in Medicine and Biology Society. Proceedings of the 23rd Annual International Conference of the IEEE [ C ],Istanbul, Turkey: The Institute of Electrical and Electronics Engineers,Inc. ,2001,3 : 2411 -2413.
  • 4HE RENJIE, PONNADA A. NARAYANA. Global optimization of mutual information: application to three-dimensional retrospective registration of magnetic resonance images [ J ].Computerized Medical Imaging and Graphics, 2002,26(4) :277 - 292.
  • 5PORTER B C,RUBENS D J,STRANG J G,et al. Three -dimensional registration and fusion of ultrasound and MRI using major vessels as fiducial markers [ J ]. IEEE Transactions on Medical Imaging, 2001,20(4) : 354 -359.
  • 6A RANGARKJAN, CHUI HAILI, DUNCAN JAMES S. Rigid point feature registration using mutual information[ J ]. Medical Image Analysis, 1999,3(4) :425 - 440.
  • 7DING L, GOSHTASBY A, SATTER M. Volume image registration by template matching[J]. Image and Vision Computing,2001,19(12) :821 -832.
  • 8BULOW H, DOOLEY L, WERMSER D.. Application of principal axes for registration of NMR image sequences[ J ]. Pattern Recognition Letters, 2000,21(4) : 329 - 336.
  • 9WACHOWIAK M P, SMOLIKOVA R, TOURASSI G D, et al. Generalized mutual information AimilArlty metrics for multimodal biomedical image registration[A]. Engineering in Medicine and Biology. 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society[C]. Houston, Texas, USA: The Institute of Electrical and Electronics Engineers,Inc. ,2002,2:1005- 1006.
  • 10LUO SHUQIAN, LI XIANG. Implementation of mutual information based multi -modality medical image registration[A] : Engineering in Medicine and Biology Society. Proceedings of the 22nd Annual International Conference of the IEEE[ C ]. Navy Pier Convention Center Chicago, Illinois,USA:The Institute of Electrical and Electronics Engineers,Inc,2000,2:1447-1450.

共引文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部