期刊文献+

修山电站发电机冷却器测温探头故障原因分析及处理措施

Reason Analysis and Countermeasures to the Failure of Temperature Measuring Probe of the Generator Cooler in Xiushan Power Station
下载PDF
导出
摘要 针对修山电站近年来发电机冷却器测温探头故障频繁,影响机组的安全运行。通过对发电机冷却器测温探头的故障原因分析,提出处理措施,从而降低发电机冷却器测温探头的故障率,提高设备的可靠性。 In view of Xiushan power plant in recent years of generator cooler temperature probe frequent failures , affect the safe operation of generator .Through the fault reasons of generator cooler temperature probe analysis , treatment measures are put forward , so as to reduce the fault of generator cooler temperature measuring probe rate , improve equipment reliability .
作者 谢中庆
出处 《广东水利水电》 2015年第3期36-38,共3页 Guangdong Water Resources and Hydropower
关键词 修山电站 发电机冷却器 测温探头 Xiushan power station generator cooler temperature measuring probe
  • 相关文献

参考文献1

二级参考文献4

  • 1赵守忠,夏勇.传感器及其应用[M].合肥:中国科技大学出版社.1997.
  • 2GB/T11805-1999,水轮发电机组自动化元件装置及其基本技术条件[S].
  • 3DL/T5081-1997,水力发电厂自动化设计技术规范[S].
  • 4周廷虎,李幼木,刘晓波.安康水电厂计算机监控系统升级改造[J].陕西电力,2008,36(12):77-80. 被引量:5