摘要 目的探讨全脑CT检查法(WBCTP)对于邻近大血管颅内肿瘤的应用价值。方法对24例确诊的邻近大血管颅内肿瘤患者进行WBCTP检查,对检查结果进行处理后得到相应的参数。结果检查的所有图形均满足相关要求;脑膜瘤的CBV和CBF高于胶质瘤,差异有统计学意义(P<0.05),而MTT与TTP两组无显著差异(P>0.05);有效辐射剂量(DLP)=5.77mSv。结论 WBCTP可以全面的反应邻近大血管肿瘤的基本情况,对于近大血管肿瘤的临床诊断具有重要作用,为手术方案提供了完善的依据。
作者 武鹏程
出处 《中国医药指南》 2015年第16期199-199,共1页 Guide of China Medicine
  • 相关文献

参考文献4

二级参考文献49

  • 1李运军,魏群.24例急性中颅窝底硬膜外血肿诊治体会[J].中国医师进修杂志(外科版),2006,29(5):59-60. 被引量:4
  • 2Pontana F, Pagniez J, Flohr T, et al. Chest computed tomography using iterative reconstruction vs filtered back projection ( Part 1 ) : evaluation of image noise reduction in 32 patients [ J ]. Eur Radi- ol, 2011,21 (3) :627-635.
  • 3Prakash P, Kalra MK, Digumarthy SR, et al. Radiation dose re- duction with chest computed tomography using adaptive statistical iterative reconstruction technique : initial experience [ J ]. J Corn- put Assist Tomogr, 2010,34( 1 ) :40-45.
  • 4Marin D, Nelson RC, Schindera ST, et al. Low-tube-voltage, high-tube-current muhidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical itera- tive reconstruction algorithm-initial clinical experience [ J ]. Radi- ology, 2010,254( 1 ) :145-153.
  • 5Hosch W, Stiller W, Mueller D, et al. Reduction of radiation ex- posure and improvement of image quality with BMI-adapted pro- spective cardiac computed tomography and iterative reconstruction [ J ]. Eur J Radiol, 2012,81 ( 11 ) : 3568-3576.
  • 6Menzei HG, Schibilla H, Teunen D. Guidelines on radiation dose on the patient[ J]. European guidelines on quality criteria for com- puted tomography, 2006,1:32-33.
  • 7Barfett JJ, Fierstra J, Willems PW, et al. Intravascular functional maps of common neurovascular lesions derived from volumetric 4D CT data [ J ]. Invest Radiol, 2010,45 (7) : 370-377.
  • 8Morhard D, Wirth CD, Fesl G, et al. Advantages of extended brain perfusion computed tomography : 9.6 cm coverage with time resolved computed tomography-angiography in comparison to standard stroke computed tomography [ J ] : Invest Radial, 2010, 45(7) : 363-369.
  • 9Mahnken AH, Bruners P, Muhlenbruch G, et al. Low tube volt- age improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarc- tion model [ J ]. Invest Radiol, 2007,42 (2) : 123-129.
  • 10Blankstein R, Bolen MA, Pale R, et al. Use of I00 kV versus 120 kV in cardiac dual source computed tomography: effect on radiationdose and image quality [ J ]. Int J Cardiovasc Imaging, 2011,27(4) :579-586.

共引文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部