摘要 简述航天推进剂加注系统的定量方式,对挤压式加注中由加注罐内气体量变化对加注系统定量精度的影响进行分析和理论计算。分析结果表明,加注罐内气体量对加注系统定量精度影响显著。为消除加注罐内气体量变化对加注系统定量精度的影响,引入一种全新的地面定量方式,即电子秤和流量积算仪组合定量方式。详细介绍了其原理、组成,并通过试验验证了其合理性。同时通过试验测试结果和理论计算公式,得到加注罐内气枕部分推进剂蒸气的含量,为推进剂蒸气的处理提供依据。 The weight measurement used in the space propellant fueling system was described. Analysis and theoretical calculation of the effect of the gas mass change on the weight measurement accuracy of the extrusion fueling system were carried out. The result of the analysis indicated that the gas mass in the filling tank had an evident effect on the weight measurement accuracy of the extrusion fueling system. In order to eliminate the effect of the gas mass change in the filling tank on the weight measurement accuracy of the extrusion fueling system, anew co-measurement method which is based on electronic weighing meter and gas flow totalizer was introduced. The principle and composition of the co-measurement were introduced in detail; and its rationality was verified by flow co-measurement experiments. Meanwhile, with the formulae that were deducted according to the result of experiment and theoretical calculation, the mass of propellant steam in the gas cavity of the filling tank could be gained, which provided a basis for the disposal of the propellant steam.
出处 《导弹与航天运载技术》 北大核心 2015年第3期93-96,共4页 Missiles and Space Vehicles
关键词 挤压式加注 电子秤定量 组合定量 加注精度 Extrusion fueling system electronic weighing meter measurement Co-measurement Weight measurement accuracy
  • 相关文献

参考文献1

  • 1宋世谟.物理化学[M].北京:高等教育出版社,1992.

同被引文献13

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部