本文根据工程实例,结合光栅光纤感温火灾探测器在罐区火灾报警系统中的应用,对光栅光纤感温火灾探测器在球罐和浮顶罐中的系统构成、安装方式进行了说明,同时阐述了罐区及其防火堤外的火灾报警系统选型及布置。
Based on an actual project, this paper details the system configuration and installation methods of grating optical fibre heat fire detector in spherical tank and floating roof tank according to the application of such fire detectors in tank farm fire alarm system and expatiates on the type selection and layout of fire alarm system in tank farm and beyond fire dike.