摘要 This paper presents a micro packaged MEMS pressure sensor for intracranial pressure measurement which belongs to BioMEMS. It can be used in lumbar puncture surgery to measure intracranial pressure. Minia- turization is key for lumbar puncture surgery because the sensor must be small enough to allow it be placed in the reagent chamber of the lumbar puncture needle. The size of the sensor is decided by the size of the sensor chip and package. Our sensor chip is based on silicon piezoresistive effect and the size is 400 × 400 μm2. It is much smaller than the reported polymer intracranial pressure sensors such as liquid crystal polymer sensors. In terms of package, the traditional dual in-line package obviously could not match the size need, the minimal size of recently reported MEMS-based intracranial pressure sensors after packaging is 10 × 10 mm2. In this work, we are the first to introduce a quad flat no-lead package as the package form of piezoresistive intracranial pressure sensors, the whole size of the sensor is minimized to only 3 × 3 mm2. Considering the liquid measurement environment, the sensor is gummed and waterproof performance is tested; the sensitivity of the sensor is 0.9 × 10-2 mV/kPa. This paper presents a micro packaged MEMS pressure sensor for intracranial pressure measurement which belongs to BioMEMS. It can be used in lumbar puncture surgery to measure intracranial pressure. Minia- turization is key for lumbar puncture surgery because the sensor must be small enough to allow it be placed in the reagent chamber of the lumbar puncture needle. The size of the sensor is decided by the size of the sensor chip and package. Our sensor chip is based on silicon piezoresistive effect and the size is 400 × 400 μm2. It is much smaller than the reported polymer intracranial pressure sensors such as liquid crystal polymer sensors. In terms of package, the traditional dual in-line package obviously could not match the size need, the minimal size of recently reported MEMS-based intracranial pressure sensors after packaging is 10 × 10 mm2. In this work, we are the first to introduce a quad flat no-lead package as the package form of piezoresistive intracranial pressure sensors, the whole size of the sensor is minimized to only 3 × 3 mm2. Considering the liquid measurement environment, the sensor is gummed and waterproof performance is tested; the sensitivity of the sensor is 0.9 × 10-2 mV/kPa.
出处 《Journal of Semiconductors》 EI CAS CSCD 2015年第6期76-79,共4页 半导体学报(英文版)
基金 Project supported by the National Natural Science Foundation of China(Nos.61025021,61434001) the ‘Thousands Talents’ Program for Pioneer Researchers and Its Innovation Team,China
关键词 intracranial pressure measurement lumbar puncture surgery BIOMEMS quad flat no-lead package waterproof test intracranial pressure measurement lumbar puncture surgery BioMEMS quad flat no-lead package waterproof test
  • 相关文献

参考文献2

二级参考文献16

  • 1M. Chopp and H. D. Portnoy, System analysis of intracranial pressure: Comparison with volume-pressure test and CSF-pulse amplitude analysis, Journal of Neurosurgery, vol. 53, no. 4, pp. 516-527, 1980.
  • 2M. Elwenspoek and J. Wiegerink, Mechanical Microsensors. Springer, 2001.
  • 3A. Ginggen, Y. Tardy, and R. Crivelli, A telemetric pressure sensor system lbr biomedical applications, Biomedical Engineering, IEEE Transactions on, vol. 55, no. 4, pp. 1374-1381, 2008.
  • 4S. S. Basati, T. J. Harris, and A. A. Linninger, Dynamic brain phantom tbr intracranial volume measurements, Biomedical Engineering, IEEE Transactions on, vol. 58, no. 5, pp. 1450-1455, 2011.
  • 5L. Lin, H. Chu, and Y. Lu, A simulation program for the sensitivity and linearity of piezoresistive pressure sensors, Microelectromechanical Systems, vol. 8, no. 4, pp. 514-522, 1999.
  • 6W. D. Nix, Mechanical properties of thin films, Metallurg. Trans. A, vol. 20A, pp. 2217-2245, 1989.
  • 7L. Zhao, C. Xu, and G. Shen, Analysis for load limitation of square shaped silicon diaphragms, Solid-State Electronics, vol. 50, pp. 1579-1583, 2006.
  • 8L. Lin anl W. Yang, Design, optimization and fabrication of surface micromachined pressure sensors, Mechatronics, vol. 8, no. 5, pp. 505-519, 1998.
  • 9B. Bae, R. Flachsbart, K. Park, and A. Shannon, Design optimization of a piezoresistive pressure sensor considering the output signal to-noise ratio, Micromechanics and Microengineering, vol. 14, no. 12, pp. 1597-1607, 2004.
  • 10S. Keshner, 1/F noise, Proceedings [" The IEEE, w)l. 70, no. 3, pp. 212-218, 1982.

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部