由于整个制冷系统安装在紧凑的整体壳体内,噪音是窗机开发过程中经常遇到的问题,从系统角度分析制冷剂压力脉动造成的低频噪音,并给出相应的处理措施。
Owing to the whole refrigerant system placed in a compact shell, noise is a normally uninvited trouble, analyse low-pitched buzz produced by pressure fluctuation from refrigerant system angle, and put forward some methods to restrain this kind of noise.