摘要
针对变电站集中监控模式下,告警信息存在信息量巨大,干扰信息多,信息频发、误发等问题,提出将告警信息进行分类管理、加延时、修改限值、挂牌屏蔽、单点抑制等信息优化处理措施,分析实际运行结果,说明告警信息优化措施正确、可行,有效提升了变电站设备安全运行的实时监视水平。
According to the problems of a huge amount of alarm information, a lot of interference information, the frequent and the false information in the centralized monitoring of substation, this paper proposes a series of processing methods containing classification management, plus time delay, modifying limit, posting placard to shield information, single-point suppression. The practical operation results show that the optimization technology of alarm information is correct and feasible,which could also improve real time monitoring level of substation equipment effectively.
出处
《河北电力技术》
2015年第1期23-24,27,共3页
Hebei Electric Power
关键词
变电站
集中监控
告警信息
信息优化
伪告警
substation
centralized monitoring
alarm information
information optimization