期刊文献+

L-环己基甘氨酸工业品中L-苯甘氨酸的HPLC测定

Determination of L-phenylglycine in L-cyclohexylglycine for industrial use by HPLC
下载PDF
导出
摘要 建立一种测定L-环己基甘氨酸工业品中L-苯甘氨酸含量的高效液相色谱(HPLC)法。色谱柱为Agela Innoval C18(250 mm×4.6 mm×5μm),采用乙腈-20 mmol/L磷酸二氢钾溶液(v∶v=8∶92)为流动相(p H 5.0)。L-苯甘氨酸在质量浓度为1.25×10-4~0.5 mg/m L时线性关系良好,相关系数r2为0.998 7。实际样品中L-苯甘氨酸日内和日间测定精密度分别为1.2%和2.7%,回收率为102.7%。所建立的HPLC方法能够很好地提供L-环己基甘氨酸样品中相关杂质L-苯甘氨酸的含量信息,并可反映出L-环己基甘氨酸的原料转化率,从而有效地指导其生产工艺的控制。 A high performance liquid chromatography-UV detection was established for the determination of L-phenylglycine in L-cyclohexylglycine industrial products. The separation was carried out on Agela lnnoval C18 column (250mm×4.6mm×5 μm), using acetonitrile-20mmol/L KH2PO4 aqueous solution (pH 5.0), 8:92 (v:v) as mobile phase in an isocratic elution. The linear range of L-phenylglycine was 1.25×10-0.5mg/mL and the correlation coefficient r2was 0.998 7. Good reproducibility was obtained in real industrial samples with intra-and inter-day relative standard deviations (RSDs) of 1.2% and 2.7%, respectively. The average recovery was determined as 102.7%. The established method provides information of the content of related impurity L- phenylglycine in the industrial L-cyclohexylglycine. The method can also reflect the conversion of reactants so as to provide information for the production process control of L-cyclohexylglyeine.
出处 《中国测试》 CAS 北大核心 2015年第2期46-49,共4页 China Measurement & Test
基金 国家973计划项目(2011CB911003) 国家自然科学基金项目(21275069)
关键词 高效液相色谱(HPLC) L-苯甘氨酸 L-环己基甘氨酸 生产工艺控制 high performance liquid chromatography(HPLC) L-phenylglycine L-cyclohexylglycine production process eontrol
  • 相关文献

参考文献19

二级参考文献90

共引文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部