城市下凹立交雨水泵站系统的升级改造 被引量:5

Upgrading and Reconstruction of Rainwater Pumping Station at Urban Underpass
原文传递
导出
摘要 城市下凹立交雨水泵站作为桥区积水的抽升设施,对城市的安全运行起着非常重要的作用。M雨水泵站通过对收水系统、提升系统、退水系统及部分附属设施的全面升级改造,其收集排放雨水的重现期设计标准由P=3年提高至P=10年,设计水量由1.1 m3/s提升至2.2 m3/s。 The rainwater pumping station at urban underpass is the pumping facility for standing water, and it plays a very important role in urban safety. The upgrading and reconstruction of harvesting, pumping and discharging systems and part of ancillary facilities of the Rainwater Pumping Station M were conducted. The design standards of recurrence interval for harvesting and discharging rainwater were improved from P = 3 years to P = 10 years, and the design pumping capacity was improved from Q = 1.1 m^3/s to Q = 2.2 m^3/s.
出处 《中国给水排水》 CAS CSCD 北大核心 2015年第12期90-92,共3页 China Water & Wastewater
关键词 下凹立交 雨水泵站 升级改造 蓄水池 underpass rainwater pumping station upgrading and reconstruction reservoir
  • 相关文献

参考文献4

  • 1何志刚,方琦.全地下式雨水泵站及调蓄池在世博会园区中的应用[J].城市道桥与防洪,2009(7):122-125. 被引量:11
  • 2GB05S518,雨水口[S].北京:中国建筑标准设计研究院,2005.
  • 3ASTMF1606--2005,采用聚乙烯(PE)内衬技术修复旧管和沟渠的标准方法[S].美国:材料与实验协会,2005.