摘要
通过个别事故案例,探讨了接触网多根支柱折断事故的抢修方案,分别从抢修方案的制定、抢修的原则、无网区的设置、接触网最低高度及惰行距离等进行探讨。
Through particular cases of accidents, discusses the rescue and repair scheme of several masts breaking accident of OCS, the discussion is made in terms of establishment of rescue and repair scheme, principles for rescue and repair, setting of non-OCS zone, minimum height of OCS and the distance of coasting etc.
出处
《电气化铁道》
2015年第3期38-40,共3页
Electric Railway
关键词
电气化
接触网
支柱
抢修
Electrification
OCS
mast
rescue and repair