期刊文献+

相位表面等离子体共振传感系统中的相差信号处理技术 被引量:6

Phase Difference Signal Processing Technology in Surface Plasmon Resonance Sensing System
原文传递
导出
摘要 为了进一步提高相位调制型表面等离子体共振(SPR)测量技术的分辨率,从相差信号解调算法方面进行了优化。基于马赫-曾德尔干涉仪结构的相位调制SPR系统中,携带传感信息的p光干涉信号与进行参考的s光干涉信号间存在着相位差。使用光电探测器和数据采集卡将两路干涉光信号采集到PC机,再结合数学计算理论和信号处理原理,最终通过设定逻辑条件选取出较理想的波形、运用锁相的思想对参与解调的光信号进行锁定、利用信号处理原理对2路光信号进行相应的处理,分析了2路干涉光在同一时刻的相位差异。基于该相差信号解调算法,一段时间内相位差异的起伏为0.006°,实现了4.7×10-7RIU(RIU表示单位折射率)分辨率的折射率测量。 In order to improve the resolution of phase modulated surface plasmon resonance (SPR) measurement technology. The signal processing technology is optimized. In the differential phase SPR biosensor based on Mach- Zehnder configuration, the SPR phase can be extracted by comparing the phase difference between the interference signals of p-polarization and the reference signals of s-polarization. The 2-path interference optical signal is recevied by computer. According to the mathematical theory and signal processing knowledge, select and processing the interference optical signals. The phase difference of 2-path signal is analyzed at the same time. In the signal processing technology, the phase difference of ups and downs is 0.006°, and the sensitivity limit is 4.7×10^-7 RIU.
出处 《中国激光》 EI CAS CSCD 北大核心 2015年第6期273-278,共6页 Chinese Journal of Lasers
基金 国家自然科学基金(61137005 11474043) 中央高校基本科研业务费专项资金(DUT14ZD211 DUT14LAB16) 国家教育部高等学校博士点基金(SRFDP 20120041110040)
关键词 传感器 信号处理 表面等离子体共振 干涉 相位测量 sensors signal processing surface plasmon interference phase measurement
  • 相关文献

参考文献10

二级参考文献86

  • 1张国文,潘军辉,倪永年.西维因和蝇毒磷的同步荧光光谱解析及应用研究[J].光谱学与光谱分析,2006,26(6):1092-1095. 被引量:15
  • 2黄显,栗大超,徐可欣,于海霞,黄福祥,胡小唐.基于微型表面等离子共振生物传感器的葡萄糖浓度测量技术[J].传感技术学报,2006,19(05B):2072-2076. 被引量:6
  • 3WOODR W.On a remarkable case of uneven distribution of light in a diffraction grating spectrum[J].Phil Magm,1902(4):396-402.
  • 4KRETSCHMANN E,RAETHER H.Radiative decay of non-radiative surface plasmons excited by light[J].Z Natur forsch,1968,23A:2135-2136.
  • 5HERMINJARD S V,SIRIGU L Z.Surface plasmon resonance sensor showing enhanced sensitivity for CO2 detection in the mid-infrared range[J].Optics Express,2009(1):3-15.
  • 6CHAH S W,YI J H.Surface plasmon resonance analysis of aqueous mercuricions[J].Sensors and Actuators,2004,99B:216-222.
  • 7ENGLEBIENNE P,HOONACKER A V.Surface plasmon resonance:principles,methods and applications in biomedical sciences[J].Spectroscopy,2003,17:255-273.
  • 8PUSTELNY T,IGNAC-NOWICKA J.Surface plasmon resonance phenomena and its application for metal phthalocyanine sensor layers investigations[J].Molecular and Quantum Acoustics,2003,24:47-59.
  • 9] Homola, S S Yeeand, G Gauglitz. Surface plasrnon resonance sensors: review EJ:. Sensors and Actuators B-Chemical, 1999, 54(1-2): 3-15.
  • 10B Liedberg, C Nylander, I Lundstrom. Surface plasmons resonance for gas detection and biosensing E J :. Sensors and Actuators, 1983, 4: 299-304.

共引文献50

同被引文献54

引证文献6

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部