摘要
为保证煤矿补偿设备的精确稳定补偿,需要准确、快速地跟踪电网电压,所以锁相技术对煤矿补偿设备极为重要。在传统基于二阶广义积分器单相锁相环的基础上,提出了一种采用三阶积分模块,对整个系统进行离散化。该改进的二阶广义积分器配合瞬时无功功率理论的单相锁相环,提高了单相锁相环的整体性能和精度。通过仿真与实验验证了该方法的有效性。
In order to ensure the accurate and stable compensation of coal mine compensation devices, it necessary to accurately and quickly track the grid voltage, so the lock-in technique is extremely important for the mine compensation equipment. On the basis of the traditional second-order generalized integrator on single-phase locked loop, proposes a third-order integral module to discrete the whole system. At the same time, the improved second-order generalized integrator coordinate with instantaneous reactive power theory of single-phase phase-locked loop, which improves the overall performance and accuracy of single-phase phase-locked loop. And verifies the effectiveness of the method through simulation and experiment.
出处
《煤矿机电》
2015年第3期89-92,97,共5页
Colliery Mechanical & Electrical Technology
关键词
二阶广义积分器
单相锁相环
瞬时无功理论
second-order generalized integrator
single-phase locked loop
instantaneous reactive power theory