电动转辙机电接点加热防霜措施研究 被引量:1

Study on Heating and Frost Protection Measures for Electrical Contact of Electric Switch Machine
下载PDF
导出
摘要 针对已经上道使用的电动转辙机在使用过程中出现电接点结霜导致接点表示不准确的情况,以ZD6系列电动转辙机为例,研究在接点罩内安装硅橡胶加热片,采用通电使加热片发热,从而达到预防电接点结霜的方案,为现场解决接点结霜问题提供有效措施。 With a view to inaccurate contact indication due to a frosty electrical contact during the application of an electric switch machine which has been put into service, by taking a ZD6 electric switch machine for instance, the paper studies on a scheme that can protect against electrical contact frost by installing a silicon rubber beating plate inside the contact cover and heating the plate by energization. In the meantime, it also determines a critical power for the heating plate in which case the contact is exactly free of frost, thus providing an effect field solution for contact frost.
作者 牛慧
出处 《铁道技术监督》 2015年第6期24-26,共3页 Railway Quality Control
关键词 电动转辙机 电接点 防霜 加热试验 Electric Switch Machine Electrical Contact Frost Prevention Heating Test
  • 相关文献

参考文献4

二级参考文献16

  • 1姬长发,黄东,袁秀玲.风冷热泵冷热水机组结霜与除霜性能的实验研究[J].西安交通大学学报,2005,39(5):480-484. 被引量:13
  • 2陆耀庆,等.实用供热空调设计手册(第二版)[M].北京:中国建筑工业出版社,2007.
  • 306K301-2,空调系统热回收装置选用与安装[S].
  • 4[4]Yonko J. D, An investigation of the thermal conductivity of frost while forming on a flat horizontal plate, ASHRAE Transaction,1967, 73(1):1.1.1~ 1.1.11
  • 5[5]Beatty K. O. Heat transfer from humid air to metal under frosting condition. Finch. E. B, Schoenborn E M. American Society of Refrigeration Engineers, 1951,59:1203 ~ 1207
  • 6[6]Kamai. S. Research on the frost formation in a low temperature cooler condenser. Mizushima T, Kifune S. The Japan Science Review, 1952, 2(3) :317 ~ 326
  • 7[7]Hayashi. Y., Study of frost properties correlating with frost formation. Aoki. A., Yuhani. H., Journal of Heat Transfer,Trans, ASME, 1977, 6(3):79 ~ 94
  • 8GB50189-2005.公共建筑节能设计标准[S].[S].,2005..
  • 9Ogawa K,Tanaka N,Takeshita M.Performance improvement of plat fin-and-tube heat exchangers under frosting conditions [J].ASHRAE Trans,1993,99(1):762-771.
  • 10Yao Y,Jiang Y Q,Deng S M,A study on the performance of the airside heat exchanger under frosting in a air source heat pump water heater/chiller unit [J].Int J of Heat and Mass Transfer,2004,47(17-18):3745-3756.