Biogenic volatile organic compound analyses by PTR-TOF-MS: Calibration, humidity effect and reduced electric field dependency

Biogenic volatile organic compound analyses by PTR-TOF-MS: Calibration, humidity effect and reduced electric field dependency
原文传递
导出
摘要 Green leaf volatiles(GLVs) emitted by plants after stress or damage induction are a major part of biogenic volatile organic compounds(BVOCs). Proton transfer reaction time-of-flight mass spectrometry(PTR-TOF-MS) is a high-resolution and sensitive technique for in situ GLV analyses, while its performance is dramatically influenced by humidity, electric field,etc. In this study the influence of gas humidity and the effect of reduced field(E/N) were examined in addition to measuring calibration curves for the GLVs. Calibration curves measured for seven of the GLVs in dry air were linear, with sensitivities ranging from 5 to10 ncps/ppbv(normalized counts per second/parts per billion by volume). The sensitivities for most GLV analyses were found to increase by between 20% and 35% when the humidity of the sample gas was raised from 0% to 70% relative humidity(RH) at 21°C, with the exception of(E)-2-hexenol. Product ion branching ratios were also affected by humidity,with the relative abundance of the protonated molecular ions and higher mass fragment ions increasing with humidity. The effect of reduced field(E/N) on the fragmentation of GLVs was examined in the drift tube of the PTR-TOF-MS. The structurally similar GLVs are acutely susceptible to fragmentation following ionization and the fragmentation patterns are highly dependent on E/N. Overall the measured fragmentation patterns contain sufficient information to permit at least partial separation and identification of the isomeric GLVs by looking at differences in their fragmentation patterns at high and low E/N. Green leaf volatiles(GLVs) emitted by plants after stress or damage induction are a major part of biogenic volatile organic compounds(BVOCs). Proton transfer reaction time-of-flight mass spectrometry(PTR-TOF-MS) is a high-resolution and sensitive technique for in situ GLV analyses, while its performance is dramatically influenced by humidity, electric field,etc. In this study the influence of gas humidity and the effect of reduced field(E/N) were examined in addition to measuring calibration curves for the GLVs. Calibration curves measured for seven of the GLVs in dry air were linear, with sensitivities ranging from 5 to10 ncps/ppbv(normalized counts per second/parts per billion by volume). The sensitivities for most GLV analyses were found to increase by between 20% and 35% when the humidity of the sample gas was raised from 0% to 70% relative humidity(RH) at 21°C, with the exception of(E)-2-hexenol. Product ion branching ratios were also affected by humidity,with the relative abundance of the protonated molecular ions and higher mass fragment ions increasing with humidity. The effect of reduced field(E/N) on the fragmentation of GLVs was examined in the drift tube of the PTR-TOF-MS. The structurally similar GLVs are acutely susceptible to fragmentation following ionization and the fragmentation patterns are highly dependent on E/N. Overall the measured fragmentation patterns contain sufficient information to permit at least partial separation and identification of the isomeric GLVs by looking at differences in their fragmentation patterns at high and low E/N.
作者 Xiaobing Pang
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2015年第6期196-206,共11页 环境科学学报(英文版)
基金 supported by the Chinese National Natural Science Foundation (41175110) the funding for the Distinguished Professor of Jiangsu Province
关键词 Biogenic volatile organic compound PTR-TOF-MS Humidity effect Reduced electric field Biogenic volatile organic compound PTR-TOF-MS Humidity effect Reduced electric field
  • 相关文献

参考文献1

二级参考文献17

共引文献50

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部