仿真体模在PET/CT图像质量及剂量控制中应用进展 被引量:4

Review of radiation dose and image quality in PET/CT with a anthropomorphic phantom
下载PDF
导出
摘要 临床PET/CT多为全身扫描,患者所受的辐射剂量较大,其中CT的剂量占较大的比例,因此如何保证临床对图像质量的要求下控制PET/CT中CT的剂量尤为重要。仿真人体等效模型是研究PET/CT中CT图像质量及辐射剂量的最佳选择。为此,对仿真人体等效模型及利用该模体对PET/CT图像质量及辐射剂量的研究进行综述,并对PET/CT中CT图像质量及辐射剂量之间的关系进行分析和讨论。 Whole-body PET/CT scanning is accompanied by substantial radiation dose in clinic. A large proportion of the radiation dose for examination obtained from whole-boby PET/CT is from CT scan. So how to control radiation dose without impairing CT image quality determined by the clinic is particularly important. Anthropomorphic phantom is the best choice for the study of radiation dose and image quality in PET/CT. The article reviews the meaning of anthropomorphic phantom and the study about PET/CT image quality and radiation dose with the phantom, Then analyzes the relationship between image quality of CT in PET/CT and radiation dose in the practical application.
出处 《中国医学装备》 2015年第6期57-61,共5页 China Medical Equipment
基金 国际科技合作项目(2009DFA32960)"PET/CT脑分子影像研究与应用平台及针灸中枢机理探索" 中国癌症基金会北京希望马拉松专项基金(LC2013A13)"PET/CT的辐射剂量和图像质量的模型研究"
关键词 正电子发射断层摄影术 体层摄影术 X射线计算机 图像质量 辐射剂量 仿真人体模型 Positron-emission tomography Tomography, X-ray computed Image quality Radiation dose Anthropomorphic phantom
  • 相关文献

参考文献5

二级参考文献25

  • 1张良安,王丹,徐志勇,戴光复,耿秀生,苏旭.放射外照射事故剂量重建中的蒙特卡罗模拟方法[J].中华放射医学与防护杂志,2004,24(6):565-568. 被引量:5
  • 2钱竞光.体操动作中的多体系统动力学原理[J].体育与科学,1995,16(5):16-19. 被引量:5
  • 3Farrelly J. Principles and applications of radiation therapy [J].Clinical Techniques in Small Animal Practice, 2003,18(2) :82-87.
  • 4ICRU REPORT 48. Phantoms and computational models in thera py, diagnosis and protection. Issued: 15 June 1992. International Commission Radiation Units and Measurements.
  • 5中国计量测试学会 电离辐射专业委员会.辐射剂量学常用数据[M].北京:中国计量出版社,1987.187,302-306.
  • 6Michael M, John D, Haris V, et al. A method of estimating fetal dose during brain radiation therapy [J]. Int J Radiat Oncol Biol Phys, 1999,44(2) :455-459.
  • 7Bliznakova K, Kolitsi Z, Pallikarakis N. A Monte Carlo based radiotherapy simulator [J]. Nuclear Instruments and Methods in Physics Research B, 2004,222(3-4) :445-461.
  • 8Andreo P. Monte Carlo application in radiotherapy [J] . Radiation Physics and Chemistry, 1998,53(3):350-351.
  • 9Si H,Geng,Chen S.Nuclear medicine scans in Beijing:insights from Beijing Quality Control Centre Survey 2005-2006[J].Nucl Med Commun, 2007,28(8) 661-666.
  • 10Kuwabara Y,Koizumi K,Ushijima Y,et al.Nuclear medicine practice in Japan.a report of the sixth nationwide survey in 2007[J].Ann Nucl Med, 2009,23(2) 209-215.

共引文献96

同被引文献54

  • 1赵建革,郭妍.医疗设备的效益分析及成本核算[J].中外医疗,2007(21). 被引量:14
  • 2朱朝晖.PET-CT技术的发展现状与展望[J].现代仪器,2004,10(4):6-11. 被引量:30
  • 3朱朝晖,傅喆.PET采集处理方法对病灶检出能力和图像质量的影响[J].现代仪器,2006,12(4):21-24. 被引量:6
  • 4吴文凯.PET/CT诊断学[M].北京:人民卫生出版社,2009:16-32.
  • 5Moses WW.Time of flight in PET revisited[J]. IEEE Transactions on Nuclear Science,2003, 50(5).1325 -1330.
  • 6Moses WW.Advantages of improved timing accuracy in PET cameras using LSO scintillator[J].IEEE Nucl Sci Syrup Conf Rec, 2002,3:1670- 1675.
  • 7NEMA NU 2-2007.Performance Measurements of Positron Emission Tomographs[S]. NEMA, 2007.
  • 8Lois C,Jakoby BW,Long MJ,et al. An assessment of the impact of incorporating time-of-flight information into clinical PET/ CT imaging[J]. J Nucl Med, 2010, 51 (2): 237-245.
  • 9Murray I,Kalemis A,Glennon J,et al.Time- of-flight PET/CT using low-activity protocols:potential implicationgs for cancer therapy monitoring[J].Eur J Nucl Med Mol Imaging, 2010,37(9) : 1643-1653.
  • 10Zhang Y,Ren L,Ling C,et al.WE-A-134- 04: Comprehensive Evaluation of a Respiration- Phase-Matched Digital Tomosynthesis(DTS) Imaging Technique for Monitoring Moving Targets[J]. Medical Physics, 2013,40(7) ~ 469-470.

引证文献4

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部