摘要 基于有限元方法模拟约束钢柱在火荷载作用下的抗火行为,分析轴向约束刚度、转动约束刚度、同向曲率的端弯矩作用对其抗火性能的影响,探讨轴向约束刚度、转动约束刚度与临界温度之间的关系。通过对约束钢柱火灾下的受力及变形性能较为全面地进行参数分析,得出:轴向约束刚度比增大,钢柱临界温度降低;转动约束刚度比增大,临界温度升高;在轴向约束条件下,截面温度分布均匀时端弯矩作用使钢柱临界温度显著降低;截面温差为200℃时,端弯矩作用的不利影响更加明显,端弯矩作用越大,受约束钢柱抗火性能越低;具有转动约束的钢柱,约束作用较小时,端弯矩作用会对其抗火性能产生不利影响,约束作用较大时,端弯矩作用对其抗火性能影响较小;截面温差为200℃时,端弯矩作用下的转动约束钢柱临界温度值几乎与轴向荷载作用下相同。另外,划分了"安全区"和"非安全区"两个区域,在抗火设计中保证钢柱的温度在安全区范围内,钢柱的抗火能力即可满足要求;端弯矩作用对约束钢柱抗火性能具有不利影响,会使安全区范围缩小。 Nonlinear finite element numerical simulation is carried out to analyze the behavior of restrained steel columns under the fire load and main attention is focused on the effects of axial and rotational restraint stiffness and external moments on the fire resistance of restrained steel columns. More comprehensive parameters are studied on the mechanics performances and deformation performances of restrained steel columns in fire conditions. The more axial restraint stiffness is, the lower the critical temperature of steel column is, and the more rotational restraint stiffness is, the higher the critical temperature of steel column is. The safe zone and unsafe zone are established, and the fire resistance of restrained steel columns is well within the safe zone. Results obtained clearly show that external moments significantly reduce the critical temperature of axially steel columns, even the adverse effects of external moments on the cross-sectional non-uniform heating profile(200℃) is more obvious, and the critical temperature of axially steel columns is lower when external moments are larger. External moments have the adverse effects on the restrained steel columns with lower rotational restraint stiffness, but they have very limited effects on the fire resistance of the restrained steel columns with larger rotational restraint stiffness and the critical temperature is almost the same as steel columns under the axial load on the cross-sectional non-uniform heating profile(200℃). External moments have the adverse effects on the fire resistance of restrained steel columns, and the scope of the safe zone decreases.
出处 《应用力学学报》 CAS CSCD 北大核心 2015年第2期333-339,360,共7页 Chinese Journal of Applied Mechanics
基金 国家自然科学基金(11272189) 山东省自然科学基金(ZR2012EEM009)
关键词 约束钢柱 数值模拟 抗火 端弯矩 临界温度 安全区 restrained columns,numerical simulation,fire resistance,external moments,critical temperature,safety zone.
  • 相关文献

参考文献9

二级参考文献43

  • 1李国强,郭士雄.受火约束钢梁在升温段和降温段行为的理论分析(Ⅰ)[J].防灾减灾工程学报,2006,26(3):241-250. 被引量:24
  • 2李国强,王培军.轴向约束梁柱在火灾引起温度沿截面不均匀分布条件下的大变形分析[J].力学季刊,2007,28(2):246-255. 被引量:6
  • 3Wang Y C. Post-buckling behavior of axially restrained and axially loaded steel columns under fire conditions[J]. Journal of Structural Engineering, 2004,130 (3): 371.
  • 4Franssen J M. Failure temperature of a system comprising a restrained column submitted to fire [J]. Fire Safety Journal, 2000,34(2) : 191.
  • 5Neves I C,Valente J C,Rodrigues J P C. Thermal restraint and fire resistance of columns[J]. Fire Safety Journal, 2002,37 (8):753.
  • 6Huang Z F, Tan K H, Ting S K. Heating rate and boundary restraint effects on fire resistance of steel columns with creep [J]. Engineering Structures, 2006,28(6) : 805.
  • 7Valente J C,Neves I C. Fire resistance of steel columns with elastically restrained axial elongation and bending[J]. Journal of Constructional Steel Research, 1999,52 (3) : 319.
  • 8Huang Z F,Tan K H. Effects of external bending moments and heating schemes on the responses of thermally restrained steel columns[J]. Engineering Structures, 2004,26 ( 6 ) : 769.
  • 9中国工程建设标准化协会.CECS200-2006建筑结构防火技术规范[S].北京:中国计划出版社,2006.
  • 10中国国家标准.GB50017-2003钢结构设计规范[S].北京:中国建筑工业出版社,2003.

共引文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部