摘要 目的探讨对急性心肌梗死合并心源性休克患者应用主动脉内气囊反搏术(IABP)的临床效果。方法选取收治的急性心肌梗死合并心源性休克患者82例作为研究对象,分为观察组和对照组(n=41),对照组行常规急诊治疗,观察组行IABP,对比2组患者血流动力学改变情况以及临床效果。结果对照组术后30、90 d的病死率分别为61.0%、68.3%,观察组则分别为36.6%、41.5%,对比差异具有统计学意义(P<0.05)。2组患者治疗前的心率、收缩压、平均动脉压以及LVEF(左心射血分数)对比,差异无统计学意义比较,治疗后比较差异有统计学意义(P<0.05)。结论应用IABP治疗能够降低术后病死率,亦可对血流动力学进行有效改善。
作者 龚晓芳
出处 《当代医学》 2015年第18期41-42,共2页 Contemporary Medicine
  • 相关文献

参考文献9

二级参考文献78

共引文献36

同被引文献24

  • 1Russ M.Intra-aortic balloon pump(IABP)counterpulsation.Do we still need it and if so when[J].Med Klin Intensivmed Notfmed,2015,110(6):402-406.
  • 2Inohara T,Miyata H,Ueda I,et al.Use of intra-aortic balloon pump in a japanese multicenter percutaneous coronary intervention registry[J].JAMA Intern Med,2015,175(12):1980-1982.
  • 3Yumun G,Aydin U,Ata Y,et al.Analysis of clinical outcomes of intra-aortic balloon pump use during coronary artery bypass surgery[J].Cardiovasc J Afr,2015,26(4):155-158.
  • 4Takahashi A,Taniguchi N,Mizuguchi Y,et al.Virtual 5-French intra-aortic pumping using a Glidesheath Slender and 6-French intra-aortic balloon catheter[J].Cardiovasc Revasc Med,2015,16(5):276-279.
  • 5Prondzinsky R,Lemm H,Swyter M,et al.Intra-aortic balloon counterpulsation in patients with acute myocardial infarction complicated by cardiogenic shock:the prospective,randomized IABP SHOCK Trial for attenuation of multiorgan dysfunction syndrome[J].Crit Care Med,2010,38(1):152-160.
  • 6Iqbal M B,Robinson S D,Ding L,et al.Intra-aortic balloon pump counterpulsation during primary percutaneous coronary intervention for ST-elevation myocardial infarction and cardiogenic shock:insights from the british columbia cardiac registry[J].PLo S One,2016,11(2):e0 148 931.
  • 7Van Nunen L X,Noc M,Kapur N K,et al.Usefulness of intraaortic balloon pump counterpulsation[J].Am J Cardiol,2016,117(3):469-476.
  • 8Bezerra C G,Adam E L,Baptista M L,et al.Aortic counterpulsation therapy in patients with advanced heart failure:analysis of the TBRIDGE registry[J].Arq Bras Cardiol,2016,106(1):26-32.
  • 9El-Halawany H,Bajwa A,Shobassy M,et al.Ischemic colitis caused by intra-aortic balloon pump counterpulsation[J].Case Rep Gastrointest Med,2015,10(2015):747 989.
  • 10García-Villarreal O A,Ramírez-González B,Salda?aBecerra M A.Left ventricular rupture of mitral valve prosthesis implantation treated using an intra-aortic balloon pump counterpulsation[J].Gac Med Mex,2015,151(6):802-805.

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部